Configuration

SETTINGS

General settings are made by CAN-wizard.
Settings and audio files can be saved on the micro SD-card.

Micro SD-card

The memory card contains the following folders:
CFG
WAV
FIRMWARE

CFG

In CFG is where the file CONFIG.FD4 is located. It has all the settings of the unit. If an empty memory card 
is inserted, the unit will by default create a catalog and write a “CONFIG.FD4-file.*

WAV

In WAV is where any sound files, used by the unit, are located. Audio files have to be in the WAV format 
(16bit, 16kHz mono), and correspond to the search path given in CAN-wizard.

FIRMWARE

When needed updated software can be added here to update the unit.

Update of software:

1.  Disconnect the power to FD4-CAN.
2.  Insert a micro SD card, that has the new software located in the folder named FIRMWARE  

for eg. “X:\FIRMWARE\FD4-CAN-03_1.0.0.bin”

3.  Press and hold the down-button on the backside of the FD4-CAN, and power up the unit. Hold the 

down-button until the upper part of the display reads “BLT” and the lower half reads the software 
version. Then release the down-button. The unit will now start.

*For transfer of settings between units see chapter “Replacing FD4-CAN”.

Summary of Contents for FD4-CAN

Page 1: ...SafeLine FD4 CAN 05 2014 Operating instructions Displays oor designations arrows and scrolling messages ENGLISH v1 06...

Page 2: ...VDC Size H x W x D 61 x 80 x 25 mm Current consumption standby Max output current on each output Max output current for the card 120 mA 24 VDC 200 mA 1 A 24 VDC Power input 19 28 VDC Input current on...

Page 3: ...ine products and accessories are copyrighted by law FD4 CAN v1 06 EN Table of contents Settings 6 Programming 7 FD4 AX Direction of the button 9 Configuration Wiring instructions 4 LED 4 Wiring instru...

Page 4: ...ARD ERR RUN TERM ERR RUN TERM TERM 20 30 VDC CAN H CAN SHLD CAN L 0V ON WWW SAFELINE SE FD4 CAN V3 R1 01 RUN ERR IO4 IO3 IO2 IO1 20 30 VDC CAN H CAN SHLD CAN L 0V SPK FD4 CAN v1 06 EN Installation WIR...

Page 5: ...and all the SafeLine products and accessories are copyrighted by law AX FD4 VW B1 AX FD4 VW B2 FD4 CAN v1 06 EN Installation BROWN GREEN YELLOW GREY WHITE 20 30 V CAN H CAN L Shield 0 V WIRING INSTRUC...

Page 6: ...files used by the unit are located Audio files have to be in the WAV format 16bit 16kHz mono and correspond to the search path given in CAN wizard FIRMWARE When needed updated software can be added h...

Page 7: ...he power to new unit 2 Insert the micro SD card from the old unit into the new unit 3 Press and hold the down button on the backside of the FD4 CAN and power up the unit Hold the button until the uppe...

Page 8: ...normal mode Do not change Node ID Correct node ID is set at delivery Press up down to set message volume Press up down to set button volume Press up down to set LED brightness Press up down to set FD4...

Page 9: ...v1 06 EN Con guration FD4 AX with one button AX FD4 VW B1 is by default delivered with the button directing down To turn it around and have the button directing up instead do the following FD4 AX DIR...

Page 10: ...aw 3 4 5 FD4 CAN v1 06 EN Con guration Disassemble the button Turn the button around so that it directs up Place it back in the circuit borad with an angle and turn it to its correct position Reassemb...

Page 11: ...11 2014 SafeLine and all the SafeLine products and accessories are copyrighted by law FD4 CAN v1 06 EN Notes...

Page 12: ...LGIUM Tel 32 0 2 762 98 10 Fax 32 0 2 762 97 10 E mail order safeline eu SafeLine Deutschland Westfalenstra e 22a D 51688 Wipperf rth DEUTSCHLAND Tel 49 0 2267 8 67 96 63 E mail order safeline eu Safe...

Reviews: