Safelincs UltraFire UBCO1D User Manual Download Page 18

18

Installation

distance: 52mm

holes of the wall

plastic stopper

Summary of Contents for UltraFire UBCO1D

Page 1: ...Digital Carbon Monoxide Alarm UBCO1D 10 Year Lifespan TEST SILENCE PPM PPM FAULT POWER ALARM Digital Carbon Monoxide Alarm USER MANUAL UBCO1D CARBON MONOXIDE ALARM...

Page 2: ...7 Digital Display 8 Alarm Memory 9 Alarm Silence Mode 10 Do Not Disturb Mode 11 Alarm Signals 12 Status Indicators 13 Positioning 14 16 Installation 16 18 Maintenance 19 22 Troubleshooting 23 24 What...

Page 3: ...ch as wood coal oil and gas The human body is unable to sense carbon monoxide in any way but it replaces oxygen in the blood when breathed in preventing the proper supply of oxygen throughout the body...

Page 4: ...Time Approx 9 hours Certified to BS EN 50291 1 2018 EN 50291 1 2018 Type of Apparatus Type B Useable Lifespan 10 years Suitable for domestic premises Product Specifications Sensor Type electrochemica...

Page 5: ...ing installing in caravans motorhomes or boats The alarm will not protect against the risk of carbon monoxide poisoning when the battery has drained Installation of the alarm should not be used as a s...

Page 6: ...eaters fireplaces fuel powered tools and operating a grill in an enclosed space The human body is unable to sense carbon monoxide in any way but the gas replaces oxygen in the blood when breathed in p...

Page 7: ...xtreme Exposure Unconsciousness cardiorespiratory failure death The dangers of carbon monoxide poisoning vary with the concentration of CO in the air and the duration of exposure As a result of this t...

Page 8: ...segments and icons for 4 seconds before resetting to show a countdown in conjunction with LED indicator lights flashing as in the Status Indicators section of this manual Once the countdown reaches z...

Page 9: ...appliance which leaks CO intermittently while the building is unoccupied is faulty and gives off CO Upon return from work or school the occupants would know that the alarm had been activated so they...

Page 10: ...sound for approximately 10 minutes The red LED will continue to flash as in alarm mode to indicate that the alarm has been silenced The alarm will automatically reset after approximately 10 minutes I...

Page 11: ...any fault low battery or end of life warning see the Status Indicators section it can be silenced for up to 9 hours by pressing the TEST SILENCE button The yellow LED will continue to flash to indica...

Page 12: ...ume to avoid startling occupants 1 Chirp 4 times with red LED flash 2 Pause 5s 3 Repeated unit it stops detecting CO Alarm 1 Chirp 4 times with red LED flash 2 Pause 5s 3 Repeated with all segments of...

Page 13: ...playing on the screen If the alarm is faulty it will chirp twice every 8 seconds with the yellow LED fault indicator flashing and Err displaying on the screen At the alarm s end of life it will chirp...

Page 14: ...as a flue running through it The recommended position for the unit should be at least 1 8 meters about 6 feet above the floor level The following suggestions are intended to help you with the placemen...

Page 15: ...llows for optimum monitoring of the red and green indicator lights Ensure that all vents of the unit are unobstructed Do not install in dead air spaces such as within 300mm from corners of walls ceili...

Page 16: ...e CO alarm Do not install in areas where the temperature is below 10 C or hotter than 45 C Do not place behind curtains or furniture within cupboards or in other enclosed or obstructed spaces CO must...

Page 17: ...ed installation position 5 Mark the installation holes with a pencil 52mm between the centres of the two holes 6 Drill the two installation holes as previously marked using a 5mm diameter drill bit 7...

Page 18: ...18 Installation distance 52mm holes of the wall plastic stopper...

Page 19: ...m does not sound the batteries may be flat please follow the Battery Replacement guidance below and then test the alarm again If the alarm still fails to react to the test button please read the Troub...

Page 20: ...us protection from carbon monoxide poisoning When using household cleaning supplies aerosols including air fresheners hair spray and deodorant or similar contaminants are used nearby the area should b...

Page 21: ...fter inserting the batteries all three LEDs will light up briefly and the alarm will beep The green LED will then flash once per second for 60 seconds then transition to standby operation a If not rem...

Page 22: ...tteries Repairing WARNING Opening up dismantling or tampering with the alarm in any way other than described in the Maintenance Battery Replacement section puts the user at risk of electrocution and m...

Page 23: ...ct the retailer if still under warranty or otherwise replace the alarm immediately The alarm will chirp 3 times every 40 seconds with the yellow LED fault indicator flashing and End on screen The alar...

Page 24: ...larm is silent and a crossed out speaker symbol is NOT on screen The alarm detected dangerous levels of CO which have since dissipated within the last 48 hours Follow instructions in the What to Do if...

Page 25: ...enter the premises 4 If anyone is suffering from the symptoms or effects of carbon monoxide poisoning seek medical advice immediately 5 Contact the relevant authority or association for your fuel typ...

Page 26: ...urchase Safelincs hereby warrants that during the warranty period commencing from the date of purchase Safelincs at its discretion agrees to repair or replace the unit free of charge The warranty on a...

Page 27: ...ied warranty of fitness for a particular purpose is limited in duration to five years This warranty does not affect your statutory rights Except for death or personal injury Safelincs shall not be lia...

Page 28: ...28 Contact Information 33 West Street Alford Lincolnshire LN13 9FX United Kingdom 0800 978 8262 support ultra fire co uk www ultra fire co uk...

Page 29: ...29 Notes 2022 Safelincs All Rights Reserved DOC 1511 Version 1 2...