Safe-T-Cover
1-800-245-6333
HCF800S-3
7. A. Align "F" (center) post in the center of the opening.
B.
Install
Inside Anchoring Brackets
(Fig 1B) at bottom of the “F” posts.
8. On outside at “D1-D2” (roof) seam, install
Roof Cover Plates
(Fig 1D) on each side of enclosure. (Fig
1D).
9. Set "C" panels and lock in place. (Solid "C" panel to be the
ACCESS DOOR PANEL
).
10. Provide ground-fault interrupter device in electrical circuit according to applicable codes. Install heater as
per manufacturer's instructions and governing local and national codes.
11. For maximum protection it is suggested that the area between the bottom of the enclosure and the
concrete base be caulked with the exception of the "C" panels.
DO NOT CAULK THE BOTTOM OF
THE "C" DOOR PANELS.
REMOVE MASKING FILM IMMEDIATELY
AFTER INSTALLATION.
If these panels get wet when the film is still on, water will
irreversibly stain the panels.
Summertime heat will bake the
film on the panels.