bead of silicone caulk into the inside bend of the “A” panel corners.)  Position both sets of assembled 
panels on the marked concrete base (Fig 2). 

3.

 

Inspect  the  alignment  of  the  “C”  (access)  panels  during  the  assembly  process.  Verify  that  their 
removal  and  replacement  allows  adequate  space  and  positioning  within  the  openings  and  with  the 
adjacent panels prior to attaching any bracket to the concrete. 

4.

 

 Set the “C” access panels in place with about a 3/16” gap on each side of the panels. 

A.

 

Set the “D” (roof) panel on the “B-A-B” assemblies.   

5.

 

Using  one  (1)  hex  headed  screw  for  each,  attach  the  Outside  Corner  Anchoring  Brackets  to  the 
“B-A-B” sections. Using one (1) anchor for each bracket, fasten them to the concrete (Fig 1A).  Fasten 
one (1) Outside Corner Anchoring Bracket at both corners on one side. 

A.

 

Attach the Inside Anchoring Brackets  to  the “B”  panels  at  the bottom, inside  at  the concrete (Fig 1B).  
Using  one  (1)  anchor  for  each,  fasten  each  bracket  to  the  concrete.    Fasten  the  Inside  Side  Anchoring 
Brackets to the “B” panels and concrete along one side of the enclosure. 

B.

 

Insert the Inside Roof Clips into the “D” (roof) panel at the “B” panel studs (Fig 1C).  Using one (1) hex 
headed screw for each, attach the clips to the “B” panels as shown. 

C.

 

Repeat Steps 5, 5A and 5B on the other side of the enclosure. 

 

NOTE: model sizes and configurations vary, see the chart.  

6.

 

Provide a ground-fault interrupter device in all electrical circuits per all applicable codes.  Install the 