Page 3
www.safe-t-cover.com 1-800-245-6333
Version 2.0
7.
Repeat the roof panel assembly for the “D2” (roof) panel on the remaining “B-A-B” (corner-end-
corner) assembly.
8.
Inspect the alignment of the “C” (access) panels during assembly. Verify that their removal and
replacement allow adequate space and positioning with the adjacent panels prior to attaching brackets
to the concrete.
9.
Place the Inner Roof Connection Bracket under the “D1-D2” 2x4 panel connection on the inside and
then fasten it into place (Fig. 2E) using Hex Head Screws.
FIG. 3
10.
Complete the bracket and clip installations in the following steps on one side before moving on to the
other side of the enclosure. Fastening each anchoring bracket will require two (2) Hex Head Screws
installed first and then one (1) Anchor per bracket installed last. Fastening each Inside Roof Clip will
require one (1) Hex Head Screw per clip.
11.
Attach Outside Corner Anchoring Brackets (small) at both “A-B” (corner) assemblies on the first side
of the enclosure (Fig. 2A) oriented as shown in the Enclosure Plan View, and then fasten them to the
concrete.
12.
Attach Inside Anchoring Brackets (large) to the “B” (corner) panel studs at the bottom, inside on the
first side of the enclosure (Fig. 2B) oriented as shown in the Enclosure Plan View, and then fasten them
to the concrete.
13.
With the “B” (middle) panel aligned in the space between the “C” (access) panels allowing
approximately a
3
/
16
” gap between panels, install Inside Anchoring Brackets (Fig. 2B) at the bottom of
the “B” (middle) panel along the first side of the enclosure.
14.
Insert Inside Roof Clips into the “D#” (roof) panels at the “B” (side) panel studs (Fig. 2C) along the
first side of the enclosure and then fasten them in place.
15.
Repeat these bracket and clip steps on the other side. Note that all provided anchoring brackets and
Inside Roof Clips must be installed for the enclosure to withstand strong winds.
16.
Install Roof Cover Plates on the “D1-D2” seam (Fig. 2D) using two (2) Hex Head Screws per plate.
17.
Provide a ground-fault interrupter device in all electrical circuits per all applicable codes. Install the
heater(s) as per the manufacturer’s instructions and governing local and national codes.
18.
For maximum protection, it is suggested that the area between the bottom of the enclosure and the
concrete base should be caulked except for the “C” panels. DO NOT CAULK THE BOTTOM OF
THE “C” PANELS.
D2