End of Life Signal – The Sensor has a 5 Year Service Life  

All 25 Series models include an End of Life (EOL) Signal indicating   
the sensor has reached the end of its service life and you must 
replace the alarm. The signal is the LED flashing RED RED 
GREEN GREEN with a beep every 25-30 seconds. The EOL Signal 
may be reset by pushing TEST / RESET button on the alarm. This 
will reset the EOL Signal for a period of 72 hours (3 days) for a total 
of up to 30 days. After 30 days the signal cannot be reset and the 
alarm must be replaced. DO NOT DISCONNECT THE ALARM 
UNTIL YOU HAVE A REPLACEMENT ALARM AVAILABLE 
TO INSTALL.

 

 

      

 

SPECIFICATIONS 

MODELS 

25-741 and 25-742 

POWER SUPPLY 

12 VDC                                   

 

NOMINAL CURRENT DRAW                       108 mA   

 

                                                                           

 

OPERATIONAL TEMPERATURE 

-40

F to +150

o

 F     -40

o

 C to +66

o

 C 

 

RELATIVE HUMIDITY 

15% (+/- 5%)  to 95% (+/- 4%)

 

AUDIBLE OUTPUT 

85 dB @ 10 feet 

 

 

GAS ALARM TRIGGER 

< 25% of the LEL of Propane  

GAS LEVEL CONFIRMATION    

8 Second Alarm Delay

 

 

CO ALARM TRIGGER  

<15 Minutes @ 400 ppm            

 

 

 

 

 

CASE DIMENSIONS 

25-741: 3.5

” W x 2.5”H x 1.25”D  

                                                                      Mounting Bracket .25"D 
 

25-742: 

4.5”W x 3.25”H x 1.25”D 

 

 
  

  

WARRANTY 

1 Year Limited  

 

TESTING LABORATORY 

ETL - Intertek 

STANDARD 

UL 1484, Fourth Edition   

 

  

 

 

 

                                                                      

 

 

OWNERS REPLACEMENT RECORD 

 

Replace this 

SAFE-T-ALERT

TM

 25 SERIES CO / GAS 

propane alarm 5 

years after date of installation / retail sale. For new RV’s enter the 
month and year the RV was manufactured. If you are not sure enter 
the  month  and  year  you  purchased  the  RV  or  enter  May  and  the 
model year of the RV (example May 2014), whichever is the earlier 
date.  
 

Installation Date / Retail Sale:________________________ 

(Example: March 2014) 

 
Replace by Date   _______________ ________________ 

(5 years after Installation date – example: March 2019) 

 

 

 

 

 
 
 
 

 

LIMITED PRODUCTS WARRANTY 

MTI INDUSTRIES, INC

. warrants to the original retail purchaser that its 

products will be free from defects of material or workmanship for a period 
of  One  (1)  year  from  the  date  of  retail  purchase.  If  proven  to  have  been 
defective in original materials or workmanship and returned, delivery costs 
prepaid, MTI INDUSTRIES, INC. will replace this product free of charge. 

 

LIMITS OF WARRANTY

 

Replacement  is  your  exclusive  remedy  under  this  limited  warranty  or  any 
other  warranty  (including  any  implied  warranty  of  merchantability  for  a 
particular  purpose).    Any  and  all  implied  warranties  or  merchantability  or 
fitness for a particular purpose shall be limited to the warranty period from 
the  original  date  of  retail  purchase.    MTI  INDUSTRIES,  INC.,  its  dealers 
and distributors shall in no case be responsible or in any way liable for any 
incidental  or  consequential  damages  for  any  reason.  Some  states  do  not 
allow the limitation or exclusion of incidental or consequential damages, or 
allow limitations on how long an implied warranty lasts, so the above 

limitations may not apply to  you.  This  warranty  gives  you specific rights, 
and you may also have other rights, which may vary, from state to state.  

 

PRODUCT NOT WARRANTED 

NOTE-

 

There are no user serviceable parts inside the case. Opening any 

SAFE-T-ALERT

TM

    product  for  any  reason  voids  the  warranty.

  This 

warranty does not cover damage or failure resulting from acts of God, abuse, 
misuse, neglect, or faulty installation

.  

 

WARRANTY RETURN PROCEDURES

  

 

It is MTI’s experience that a CO / Propane Gas Alarm is sounding for a 
reason. Call, ask your dealer to call, or e-mail our Customer Service 
Department (as listed below) to trouble shoot the situation. 
  

Customer Service Phone No. -  800-383-0269    
Fax  No. 847-546-9007 
E-mail [email protected]  
Web Site: www.mtiindustries.com  

 

If Customer Service determines that the unit is defective, a Return 
Authorization (RA) number will be issued.  

No product will be accepted 

for service or replacement without first obtaining a RA number. 

 

If authorized, return this product to: 
 

MTI Industries, Inc.  
Warranty Dept. RA # (

INSERT RA NUMBER HERE

31632 N. Ellis Drive Unit 301  
Volo, IL 60073   

NOTE:  Mark the RA number in the area shown on the outside 
of the box! 

NOTE:  
 

25-741 and 25-742 are the basic dual CO / LP Gas alarm with no 
interconnection and no relay. If you want these features order a custom  
70-742 from MTI Industries. 
 

© MTI INDUSTRIES, Inc. 2013

 

 

Summary of Contents for 25-741

Page 1: ...uss these symptoms with ALL household members and RV guests Mild Exposure Headaches running nose sore or watery eyes often described as flu like symptoms Medium Exposure Dizziness drowsiness vomiting Extreme Exposure Unconsciousness brain damage and death NOTE Reported cases of CO gas poisoning indicate that while victims are aware they are not well they are disoriented They are unable to save the...

Page 2: ...chen area near sources of a potential gas leaks Some potential sources are a furnace refrigerator stove or oven If potential sources of a gas leak are in separate areas MTI recommends installing a gas alarm in each area The Consumer Product Safety Commission recommends installing a CO alarm outside the sleeping area The 25 series combination CO and gas alarm complies with that recommendation INSTA...

Page 3: ...Shooting Guide in this manual for further information Do not attempt to fix it yourself Gas Alarm When you power the alarm it has a warm up period of approximately 1 minute This unit cannot go into a gas alarm during the warm up period After 1 minute the alarm can detect explosive gas Simultaneous CO and Gas Alarms Because the risk of a propane gas explosion is generally a more serious danger your...

Page 4: ... for your country The emergency number depends on your travel location Two self adhesive labels are included with this Alarm Add the phone numbers of your emergency service provider and qualified technician in the space provided Place one label near the alarm and one label near a fresh air source where you plan to gather if the alarm sounds PROCEDURES TO TAKE DURING A CO ALARM IN THE USA WARNING A...

Page 5: ...orkmanship and returned delivery costs prepaid MTI INDUSTRIES INC will replace this product free of charge LIMITS OF WARRANTY Replacement is your exclusive remedy under this limited warranty or any other warranty including any implied warranty of merchantability for a particular purpose Any and all implied warranties or merchantability or fitness for a particular purpose shall be limited to the wa...

Reviews: