INTEGRA-X User Manual
WEB GUI
SAF Tehnika JSC
51
Figure 3-42
6)
Set all to default
– Restores default settings for all groups and sensors.
7)
By pressing
„Execute configuration”,
changes made to the corresponding section apply only
to the local side Integra-X.
CLI commands
See Chapter 4: COMMAND LINE INTERFACE
log group info
Use to show sensor group configuration.
log group create <name>
<description>
Use to create a new group.
log group mgmt <name> add
destination {event|perf|snmp|syslog}
Use to add a destination for a group.
log group mgmt <name> add sensor
<sensor>
Use to add a sensor to a group.
log group mgmt <name> config
{enable|disable}
Use to enable or disable a group.
log group mgmt <name> delete
Use to delete a group.
log group mgmt <name> remove
destination {event|perf|snmp|syslog}
Use to remove a destination from a group.
log group mgmt <name> remove
sensor <sensor>
Use to remove a sensor from a group.
log sensor info
Use to show current sensor status.
log sensor list
Use to list all available sensors.
log default {all|group|sensors
[<sensor>]}
Use to set group, individual sensor or all sensor
configuration to default.
Performance
Alarm
Alarm threshold configuration
The page, see
provides a summary of the parameters’ alarm thresholds. All
thresholds are predefined and some change dynamically according to the system
configuration. Thresholds can be modified if required.
Alarm activates when current value exceeds (low-delta) or (high+delta) values. Alarm
deactivates when current value exceeds (low+delta) or (high-delta) values.