11
XL-PH10409UM-en-US Rev C · 2012-08-03 · Amendments and errors reserved. © SAF-HOLLAND, Inc.
Figure 12
Mounting Instructions
4. Install the air chamber by aligning the
air chamber assembly and plunger with
the pintle hook. Make sure the plunger
moves freely within the pintle hook
plunger chamber
(Figure 7)
. Attach
the air chamber to the assembly using
the air chamber hardware
(Figure 12)
.
5. Connect the air supply to the air chamber
and check for proper operation.
IMPORTANT:
Consult the vehicle
manufacturer for
information regarding
proper plumbing,
air source, and
overpressure protection.
6. Adjust the plunger as needed per detailed
instructions in Section 12, page 12.
"*3$)".#&3