English
English
16
Advanced menu
Menu GTAW
To enter into Menu GTAW see section Menu, described
above
Menu GTAW
Function Factory
Configuration
Default
Selectable Value Range
Displayed
parameter
name
Displayed
value
Wave Form
SQRE
SOFT
WAVE
Current
selected value
type
SINE
SQRE
TRI
Tungstene size
AUTO
AUTO (Note D)
DIA
Current
selected value
0.5mm (0.02”)
1mm (0.04”)
1.6mm (1/16”)
2.4mm (3/32”)
3.2mm (1/8”)
4mm (5/32”)
ADV (Note E)
Tungsten Type (Note
F)*
GRN
GRN
TYPE
Current
selected value
Colour
WHTE
GREY
TURQ
GOLD
Restart 2S
OFF
ON/OFF
2RST
Current
selected value
(-)
Restart 4S
OFF
ON/OFF
4RST
Current
selected value
(-)
Bi-Level function
OFF
ON/OFF
BILV
Current
selected value
(-)
Spot function
OFF
ON/OFF
SPOT
Current
selected value
(s)
TIG STARTING PARAMETERS
Function Factory
Configuration
Default
Selectable Value Range
Displayed
parameter
name
Displayed
value
Polarity
EP
EN/EP
POL
Current
selected value
(-)
Amperage
120
2 – 200A (step 1A)
SCRT
Current
selected value
(A)
Time
100
1 – 1000ms (step 1ms)
STME
Current
selected value
(ms)
Start Slope Time
40
0 – 1000ms (step 1ms)
SSLP
Current
selected value
(ms)
Preset Amperage Min
5
2-50A (step 1A)
PCRT
Current
selected value
(A)