11
Connecting the chimney
The stove must be connected to a chimney in accordance with the applicable standards and on the basis
of the inspection report issued. The installation must be carried out only by an authorised expert in
chimneys.
The stove can only be started up after an inspection of the chimney and after the stove has been properly
connected by the relevant specialist.
During the first start-up, it is advisable not to use any other appliance (hoods, fans, other stove) in order
to check the stove correctly.
Top connection and rear connection
The design of the stove offers two ways of connecting the stove pipe:
- rear connection (supplied ex-factory as standard, see figure 11);
- top connection (must be installed in accordance with the following instructions).
Conversion to top connection
The components required to convert the stove to a top connection are supplied
with the appliance: cast iron adapter ring (1pc), seal (1pc), enamelled cap (1pc), 4
self-tapping screws (see fig. 10)
Replacing the stove's flue pipe
1. Remove the top cast iron plate from the stove. On the inside, remove the metal
piece securing the round cover plate (see Fig. 12).
2. Remove the control extension rod from the gas valve (Fig. 11).
3. Remove the back plate of the metal plate to gain access to the connecting flange
and remove the flange. Make sure the original seal is installed here, which should
be used for the new assembly.
4. Carefully remove the metal round plate and the seal at the top, this will be used to seal the original
rear exhaust. Check again that the seal is correctly installed.
The tightness of this round plate is vital for the safe operation of the stove.
5. Screw on the removed connection flange and seal it to the top (see Fig. 13). The round plate covering
the original rear outlet can also be seen here.
6. Screw the enamelled sheet metal cover supplied onto the rear flap and replace the entire rear flap
on the stove.
7. Install the cast iron cover. Use the cast iron adapter ring supplied by the manufacturer to maintain
the space between the cover and the newly installed stove socket (see figure 14).
8. Reinstall the gas valve control extension rod and check for proper operation.