S
AEY
FENIX
/
SAEY
FENIX
VITRO
810.6011.000 / 02
76
English
12 T
ECHNICAL DATA
Results
Fenix
VITRO 70
Fenix
VITRO 80
Fenix
VITRO 90
Power range
kW
6 - 12
7 - 14
7
– 14
Nominal power
kW
9
11
11
Performance
%
73.5
73.5
73.5
CO-eùissions (at 13% O2)
%
0.24
0.24
0.24
Particle emissions
Mg/Nm³
62.9
62.9
62.9
Fume temperature at nominal power
°C
310
310
310
Size and weight
Rear connection
yes/no
no
no
no
Space to heat (indicative)
m³
220
260
260
Weight
Kg
101
112
122
Installation values
Hearth draught at nominal power
Pa
12
12
12
Hearth draught limits
Pa
10 - 20
10 - 20
10 - 20
Supply of fresh air
m³
42 - 50
51
51
Fuel
Consumption at nominal power
Kg
3.0
4.0
4.0
Consumption at maximal power
Kg
3.6
4.7
4.7
Maximum humidity
%
20
20
20
Maximum length
cm
50
50
50
Maximum diameter
cm
18
20
20
Electrical scheme for the connection of the fan.