S
AEY
94
/
S
AEY
94
C
UCINA
30042013
– v03
29
ENGLISH
5
T
ECHNICAL DATA
Characteristic
Unity
SAEY 94
SAEY 94 Cucina
Nominal heat output
kW
9
9
Minimum – maximum heat output
kW
4 – 13
4 – 13
Efficiency
%
77
77
CO emission (at 13% O2)
%
0,12
0,12
Dust emission
Mg/Nm³
22
22
T° flue gasses at nominal heat output
°C
316
316
Flue gas mass flow
g/s
8,25
8,25
Dimensions and weight
Height
mm
745
770
Width
mm
640
640
Depth
mm
540
540
Flue outlet
top or rear
rear
Distance middle flue outlet – floor
mm
595
595
Distance middle flue outlet – rear
mm
170
-
Ø flue outlet
mm
150
150
Weight
kg
161
174
Installation data
Chimney draught at nominal heat output
Pa
12
12
Recommended chimney draught
Pa
10 - 20
10 - 20
Supply fresh air
m³/h
35
35
Fuel - wood
Fuel
wood
wood bricks
wood
wood bricks
Fuel consumption at nominal heat output
kg/h
2,69
2,69
Fuel consumption at maximal heat output
kg/h
4,00
4,00
Maximum humidity
%
20
20
Maximum log length - horizontal
mm
440
440
Maximum log length - diagonal
mm
480
480
Maximum diameter
mm
300
300
Summary of Contents for 94