background image

18

Precautions and warnings “after” the use of equipment

- Turn off the main switch of the chair when it is not in use for an extended period of time.

- Always maintain the equipment clean for the next operation.

- Do not modify any part of the equipment. Do not disconnect the cable or other connections 

without need.

Precautions and warnings during the “cleaning” of equipment

- Before cleaning the equipment, turn off the main switch.

- Avoid spilling water or other liquids inside the equipment, which could cause short circuits.

- Do not use microabrasive material or steel wool when cleaning, or employ organic solvents or 

detergents which contain solvents such as ether, stain remover, etc.

- In order to avoid environmental contamination or undue use of the Equipment after it has become

useless, it should be discarded in the suitable place (as per the local legislation of the country).

- Pay attention to the local legislation of the country for the conditions of installation and disposal

of residue.

Precautions to be adopted against foreseeable or uncommon risks, related to

the deactivation and abandoning of equipment

- If the equipment has any abnormality, check if the problem is related to any item listed in the 

topic  of  unforeseen  events  (failures,  causes  and  solutions).  If  it  is  not  possible  to  resolve  the 

problem, turn off the equipment, remove the power supply cable from the socket and contact your 

representative (Alliage).

Precautions in case of alteration in the functioning of equipment

Manufacturer shall not be responsible for: 

- Use of the equipment differing from that for which it is intended.

- Damages caused to the equipment, the professional and/or the patient by the incorrect installation

and erroneous procedures of maintenance, differing from those described in these Instructions for

use which come with the equipment or by the incorrect operation of it.

PRECAUTIONS, RESTRICTIONS AND WARNINGS

Summary of Contents for 40L

Page 1: ......

Page 2: ...ni industrial LTDA C N P J 59 064 766 0001 82 Avenida Professora Luiza Garcia Ribeiro 130 Santa Rosa de Viterbo SP Brasil For improved safety Read and understand all the instructions contained in the...

Page 3: ...arnings during the installation of the equipment 17 Recommendations for preserving the equipment 17 Precautions and warnings during the use of equipment 18 Precautions and warnings after the use of eq...

Page 4: ...pment is for dental use use only It must be operated and utilized by specialized professional certified professional according to the legislation of the country and following the instructions of the m...

Page 5: ...ate the equipment s operation and maintenance Safety System with valve that starts running for pressure release if there is any failure from the pressure switch and overload shield in order to protect...

Page 6: ...gine 05 On off switch 06 Inner pressure gauge manometer 07 Safety valve 08 Overload protector 09 Register of the outlet pressure 10 Manometer of the outlet pressure 11 Outflow rate register 12 Drainag...

Page 7: ...ral features Supply voltage and frequency 40 and 65 Liters 220V 10 60Hz or 127V 10 60Hz Supply voltage and frequency 150 Liters 220V 10 60Hz Rated current 40L 127V 13 A 40L 220V 6 7 A 65L 127V 13 A 65...

Page 8: ...cfm 65l 283 l min 10 cfm 150l 566 l min 20 cfm Max pressure 40l 120 psi 8 3 bar 65l 120 psi 8 3 bar 150l 120 psi 8 3 bar Number of Cylinders 40l 2 65l 2 150l 2x2 Other specifications Head weight 40L...

Page 9: ...9 Dimensions 40 LITERS TECHNICAL SPECIFICATIONS...

Page 10: ...10 Dimensions 65 LITERS TECHNICAL SPECIFICATIONS...

Page 11: ...11 Dimensions 150 LITERS TECHNICAL SPECIFICATIONS...

Page 12: ...ay from direct sun light exposure Packing to be transported and or stored with care should not suffer drop and neither receive impact Temperature limit for the packing to be stored or transported Turn...

Page 13: ...ute this task Alliage bears no responsibility for damages or accidents caused by poor installation executed by a technician not authorized by Alliage Only after the equipment has been installed and du...

Page 14: ...2 psi and so successively and automatically If the pressure switch fails the safety valve 07 will start running by releasing the excessive pressure Voltage Rated current Circuit breaker 127V 10 13 A 1...

Page 15: ...sal Open the register slowly until all the accumulated water is drained and air starts to flow again Close the register firmly so that no leakage can occur Compressed air outlet The air pressure on th...

Page 16: ...hPa to 1060 hPa 525 mmHg to 795 mmHg Operation altitude 2000m Attention The Equipment maintains its condition of safety and efficacy provided that it is maintained stored as mentioned in this instruct...

Page 17: ...apacity while using it does not exceed their technical specifications Alliage assumes no liability for damages accidents resulting from improper use or non compliance with the instructions described i...

Page 18: ...islation of the country Pay attention to the local legislation of the country for the conditions of installation and disposal of residue Precautions to be adopted against foreseeable or uncommon risks...

Page 19: ...eventive Maintenance The equipment should be calibrated routinely as per the legislation in force in the country But never with a period exceeding 3 years In order to protect your equipment seek Allia...

Page 20: ...rective Maintenance Alliage states that the supplying of the circuits diagram Part lists or any other information that permits the technical assistance by the user can be requested since previously ag...

Page 21: ...an the specified Connect the compressor to the correct network Wait for the regularization of network The compressor does not re aches the maximum pressure lesser efficiency works for a short period o...

Page 22: ...resentative We call your attention to our authorized resellers chain Only this chain will keep your equipment constantly new because it has trained technical assistant and specific tools for the corre...

Page 23: ...23...

Page 24: ......

Reviews: