If the machine is not heating , check the following:

 

a- the 
thermos
tat (mo
unted 
on the 
heat 
exchan
ger and 
steam 
boiler if 
present
).

  

b- the 
heating 
element  
(on the 
lower 
side, not 
seen in 
the 
picture). 

c- the 
thermof
use

 

d- the electronic sensor that initially brings water to temperature for espresso.  

 

  

Finally, before replacing the top cover, make an espresso with coffee. To do so, 
use the preground cycle with ground coffee or hold the bean hopper on the 
grinder inlet and add beans  in the bean hopper just enough for one espresso 
(excess beans will spill around and  inside   and be difficult to clean, especially 
from around the doser assembly. (Vacuum the spilled beans out) 

  

If all functions are working good, the coffee grind is like the table salt grain, and 
still the espresso is not dispensed, the chances are that the 

 

1- pump is weak and unable to exert the pressure necessary to pump water 
through the tamped coffee grounds. Replace the pump.

 

2- the heat exchanger outlet nozzle is blocked or its lower end is broken. Replace 
the nozzle.

 

3- Th brew group is blocked. Clean the shower screen & the valve under the 
outlet nozzle flange.

 

  

To remove the pump

, avoid removing the pump mounting pads (it is a lot of 

work). 

 

  