12
Before you slide the brew group back into the machine, make sure the
two reference signs on the side match. If they do not match, perform the
following step:
-
Make sure the lever is in contact with the base of the brew group.
13
Make sure that the locking hook of the brew group is in the correct
position.
-
To position the hook correctly, push it upwards until it is in uppermost
position.
-
The hook is not correctly positioned if it is still in bottommost position.
14
Slide the brew group back into the machine along the guiding rails on the
sides until it locks into position with a click.
Caution: Do not press the PUSH button.
15
Close the service door.
Monthly lubrication of the brew group
Lubricate the brew group after the machine has brewed 500 cups of coffee
or once a month.
1
Switch off the machine and unplug it.
2
Remove the brew group and rinse it under a lukewarm tap as described
in section 'Weekly cleaning of the brew group'.
23