Cause
Error
Code
Machine without snack
slaves
Machine With
Snack Slaves
Notes / Recommended Intervention
Instant product
boiler
temperature
sensor reading
out of range
13
Models with 2 boilers
==>beverages with instant
products not available
Beverages with
instant products
not available
Check the coffee boiler (connections,
thermostats, temperature sensor).
Instant Models ==> Vending
machine out of service
Coffee
temperature
sensor reading
out of range
14
Models with 2 boilers ==>
coffee beverages not
available
Models with 2
boilers ==>
coffee beverages
not available
Check the coffee boiler (connections,
thermostats, temperature sensor).
Models with 1 boiler ==>
Vending machine out of
service
Models with 1
boiler ==> no
beverage
available
Cup holder
movement not
detected
17
No more cups warning
No more cups
warning
Warning report only in the LOG.
“No more cups” message is displayed.
The vending machine can still dispense
beverages without cups.
Fill in the cup columns.
Check the cup dispenser.
Brew group not
detected
20
Coffee beverages not
available
Coffee beverages
not available
Warning report only in the LOG.
“No more coffee beans” message is displayed.
Check the brew group inserting status.
Abnormal coffee
brewing flow
detected
22
Coffee beverages not
available
Coffee beverages
not available
Check the brew group cleaning.
Set a coarser coffee grind.
Check the flowmeter.
No filling of the
instant product
boiler
24
Models with 2 boilers
==>beverages with instant
products not available
Beverages with
instant products
not available
Check the instant product boiler water
circuit.
Instant Models ==> Vending
machine out of service
Air sensor error
27
---
The slave is
disabled (only if
the refrigerator
is enabled)
Check the air temperature sensor
connection.
Evaporator
sensor error
29
---
Warning only
Warning report only in the LOG.
Check the evaporator temperature sensor
connection.
Decimal point
position setting
not consistent
with the
payment system
31
Vending machine out of
service
Vending machine
out of service
Check for consistency between decimal
point settings in the vending machine and
in the payment system
Credit management
restart
32
Warning only
Warning only
Warning report only in the LOG.
Warning for normal
situation restoring
after abnormal flow
34
Warning only
Warning only
Warning report only in the LOG.
Check the ground coffee granulometry.
MDB slave error
detected
35
Warning only
Warning only
Warning report only in the LOG.
Slow coffee
boiler warm-up
36
Vending machine out of
service
Beverages not
available
Check the coffee boiler (connections,
thermostats)
Summary of Contents for Atlante 500
Page 26: ...English 5 26 Standard product configuration Atlante 500 Instant ...
Page 27: ...English 5 27 Standard product configuration Atlante 700 Instant ...
Page 28: ...English 5 28 Standard product configuration ATLANTE 500 1 macina ...
Page 29: ...English 5 29 Standard product configuration ATLANTE 700 1 macina ...
Page 30: ...English 5 30 Standard product configuration ATLANTE 500 2 macina ...
Page 31: ...English 5 31 Standard product configuration ATLANTE 700 2 macina ...
Page 90: ......
Page 91: ......
Page 92: ...Cod 15001683 Ed 07 Powered by TCPDF www tcpdf org ...