PROBLEMS
CAUSES
REMEDIES
The machine does not
turn on.
The machine is not
connected to the power
supply.
Move the main switch to ON.
Check the plug and the
connection
The coffee is not hot
enough.
The cups are cold.
Warm up the cups.
No hot water or steam is
dispensed.
The tube nozzle is clog-
ged.
Clean the nozzle opening with
a needle.
During this operation,
the knob must be
closed and the machine
must be off.
A noise can be heard
coming from the steam
tube of the machine.
The machine takes a long
time to warm up.
Excessive scale has
built up.
Descale the machine.
The brew unit cannot be
removed.
The unit has stopped in
the wrong position.
Close the door and switch on
the machine; the brew unit will
move back into position.
PROBLEMS - CAUSES - REMEDIES
PROBLEMS
CAUSES
REMEDIES
Coffee fl ows out in slow
trickle or not at all.
Excessively fi ne grind
and too much coffee.
Adjust to a coarser grind (turn
the knob clockwise).
Decrease the quantity.
36