002AZ001A
6 - 13
OPERATING INSTRUCTIONS
6
6.5.6
CORRECT POSITION FOR START OF FORMING CONTROL
DESCRIPTION
A pair of inductive sensors, secured to the base near the point in which the box distributor opens the high pressure port,
detect the start of the forming stroke. If both or none of these sensors are activated by the measurement rod, the machine
performs the emergency cycle illustrated in the flow chart below.
DIAGRAM
1
incorrect position detected
2
error counter per run activated
counter control = 32
3
start of delay time for stoppage due to defective product
yellow warning light comes on
control end of delay time for stoppage due to defective caps
4
end of cycle
RESET
As seen in the diagram a time during which the operator can intervene to reset the correct flow of oil under low pressure.
If no action is taken, the machine carries out the operations for end of cycle and then proceeds as described in the
DOUBLE PRODUCT DETECTION paragraph.