SOUTHERN AVIONICS COMPANY
SE Series Installation and Setup
6-11
System Site Configuration
WEB WATCH
(Locally connected)
In the SE SERIES TRANSMITTER Web Watch window, click on
Calibration
in the right column
box on the
Main
window to open the
Transmitter 1 : Calibration
window shown in Figure 6-4.
Operation is similar to the LCD DISPLAY above. Click set to activate the change.
Figure 6-4. Web GUI Transmitter Calibration Window
6.5.2 Modulation Calibration (Read only)
LCD DISPLAY
Press the
4
key to open the
MODULATION CALIBRATION
menu, as shown below.
Set the modulation level to 100%. Verify that this is actually 100% modulation by monitoring the
RF waveform envelope on the dummy load. Vary the MOD Factor and press enter. Do this until
the scope displayed modulation is correct.
-------- MODULATION CALIBRATION -------
MOD Factor should be between 5 and 250.
Enter modulation factor: [100]