An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.

When Installing the Unit

     Never   plug  in   nor remove the power  supply   plug
    with  wet  hands,  as  doing  so  may cause electric
    shock.

     When unplugging   the  power   supply cord, be sure
     to grasp the   power  supply   plug; never  pull on the
    cord  itself.  Operating   the  unit   with  a  damaged
    power  supply  cord  may  cause  a  fire  or  electric 
    shock.

     When moving the unit, be sure  to remove its power 
     supply cord   from the  wall   outlet.  Moving   the unit
     with the   power  cord   connected  to   the outlet may
     cause damage to the power cord,  resulting in fire or 
     electric shock. When   removing the power cord,  be
     sure to hold its plug to  pull.

  Do not block the ventilation slots in the unit's cover.
  Doing so may cause heat to build up inside the unit 
  and result in fire.

  Avoid installing the unit in humid or dusty locations,
  in locations exposed to the direct sunlight, near the 
  heaters, or in locations generating   sooty smoke or
  steam  as  doing  otherwise  may  result  in  fire  or 
  electric shock.

When the Unit is in Use

     Do  not place heavy objects  on the unit as  this   may
    cause   it  to  fall  or  break   which   may   result   in 
    personal   injury    and/or    property    damage.   In
    addition,  the  object  itself  may  fall  off  and  cause
    injury  and/or  damage.

    Make  sure   that   the  volume   control   is   set   to
    minimum  position   before  power  is  switched   on.
     Loud noise produced at high volume when power  is 
    switched  on  can  impair  hearing.

     Do not operate   the  unit   for an  extended   period of 
     time with   the sound distorting. This  is   an indication
     of   a  malfunction,   which  in   turn  can cause heat to
     generate and result in a fire.

     Contact your SABRE dealer as   to the  cleaning. If   dust
    is  allowed  to accumulate  in  the  unit  over  a  long 
    period of  time, a  fire  or  damage  to  the  unit  may 
    result.

  If   dust  accumulates   on the  power supply plug or in
  the   wall   AC   outlet,  a   fire  may   result.  Clean  it 
  periodically. In  addition, insert   the  plug   in  the  wall 
  outlet securely.

  Switch  off t he  power, and unplug  the  power  supply
  plug   from the  AC outlet   for  safety   purposes  when 
  cleaning   or  leaving  the unit unused for  10  days  or 
  more. Doing otherwise   may cause a fire  or   electric 
  shock.

 SAFETY PRECAUTIONS

4

Summary of Contents for SA-20B

Page 1: ...REBLE MIC2 TEL OUTPUT LEVEL 2 4 6 8 10 PROT POWER MIC1 AUX MASTER ON OFF 0 0 0 0 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 6 7 7 7 7 8 8 8 8 9 9 9 9 10 10 10 10 5 5 0 0 1 1 2 2 3 3 4 4 1 1 2 2 3 3...

Page 2: ...TABLE OF CONTENTS 1 SAFETY PRECAUTIONS 3 2 SA 20B 40B MIXER AMPLIFIER 5 3 SA 60B 120B MIXER AMPLIFIER 14 2...

Page 3: ...in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid electri...

Page 4: ...sooty smoke or steam as doing otherwise may result in fire or electric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in pe...

Page 5: ...and 1 channel 300mv 10Kohms AUX input 4 1 channel MIC1 balanced unbalanced input 2 5 5mv 1 2Kohms 5 1 channel TEL input sensitivity 1 6 builin treble bass adjusting bass 10dB at 100Hz treble 10dB at...

Page 6: ...treble response Rotate clockwise to increase treble output and anticlockwise to reduce it 7 MASTER Master volume control 2 NOMENCLATURE AND FUNCTIONS 8 POWER Power indicator 9 POWER SWITCH On top of t...

Page 7: ...rride all the other inputs 15 MIC input with phantom power MIC1 input compatible of XLR and MIC 16 MIC 1 PHAN TOM 48V Power switch 17 MIC 2 MIC input MIC2 input of MIC 18 AUX input AUX for extra equip...

Page 8: ...70V 100V COM 4 16 70V 100V COM 4 16 SA 20B 500 100V LINE 70V 100V COM 4 16 SA 20B 245 70V LINE 3 1 SPEAKER CONNECTIONS 4 2 XLR CONNECTIONS 4 16 3 CONNECTIONS 70V 8 SA 40B 125 SA 40B 250...

Page 9: ...The four output connectors only can choose two connectors work together If voltage is 70V 100V the speakers must be with transformer and make sure the total power wattage of speaker is 15 less than th...

Page 10: ...1 AUDIO OUT R L COM AUDIO SOURCES LINK INPUTS XLR BAL 1 GND 2 HOT 3 COLD 1 2 3 1 2 3 OUTPUTS INPUTS POWER AMPLIFIER 10 LINE OUT AUX MIC 2 MUTE MIC 1 XLR 6 30 INPUT BAL UNBAL 48V PHANTOM OUTPUTS COM 4...

Page 11: ...6 BLOCK DIAGRAM COMP COMP GAIN AMP GAIN AMP GAIN AMP POWER AMP GAIN AMP 11...

Page 12: ...y response At 1KHz Half power output MIC1 2 input section MIC in 1Khz preamp out Input sensitivity impedance AUX input section AUX in 1Khz preamp out SA 40B 4 16 70V 100V 20W 1V 1KHz 80Hz 16KHz 1dB 3d...

Page 13: ...POWER MIC1 AUX MASTER ON OFF 5 5 0 0 1 1 2 2 3 3 4 4 1 1 2 2 3 3 4 4 5 5 5 0 1 2 3 4 6 7 8 9 10 LINE OUT AUX MIC 2 MUTE MIC 1 XLR 6 30 INPUT BAL UNBAL 48V PHANTOM OUTPUTS COM 4 16 70V 100V TEL INPUT...

Page 14: ...ies with min noise and high fidelity even at high volume 4 Reliable protection against overload short ciruit and power fluctuation for optimum reliability 5 VOX feature mutes AUX inputs when input is...

Page 15: ...ATURE AND FUNCTIONS 9 POWER Power indicator 10 LEVEL INDICATORS Level meters 6 output level indicators 11 PROT 12 TEMP Temperature Indicator When the machine is in protection status this indicator wil...

Page 16: ...uts 16 MIC input with phantom power MIC1 input compatible of XLR and 6 3 MIC 17 Fantasy power button switch 18 MIC 2 MIC 3 MIC input MIC2 3 input of 6 3 MIC 19 TEL INPUT 20 AUX 1 AUX 2 AUX input AUX 2...

Page 17: ...70V 100V COM 4 16 70V 100V COM 4 16 SA 60B 167 100V LINE 70V 100V COM 4 16 SA 60B 81 70V LINE 3 1 SPEAKER CONNECTIONS 4 2 XLR CONNECTIONS 4 16 3 CONNECTIONS 70V 17 SA 120B 41 SA 120B 83...

Page 18: ...he four output connectors only can choose two connectors work together If voltage is 70V 100V the speakers must be with transformer and make sure the total power wattage of speaker is 15 less than the...

Page 19: ...DIO SOURCES LINK INPUTS XLR BAL 1 GND 2 HOT 3 COLD 1 2 3 1 2 3 OUTPUTS INPUTS POWER AMPLIFIER SPEAKERS MIC 2 MIC1 MIC 3 TEL INPUT MIC2 MIC3 MUTE G TEL INPUT AUX2 AUX1 LINE OUT MIC 1 XLR 6 30 INPUT BAL...

Page 20: ...6 BLOCK DIAGRAM 70V COM 4 TO PA BASS TREBLE VOLUME PROTECT LEVEL INDICATOR POWER Z 220V 50Hz PT COM 100V COM EB EB LINE OUT MIC1 MIC1 MIC2 MIC3 AUX1 AUX2 TEL MUTE MUTE 20...

Page 21: ...control Bass 100KHz Treble 10KHz Phantom power AUX 1 input section AUX in 1Khz preamp out Input sensitivity impedance S N Frequency Response 3dB Tone control Bass 100KHz Treble 10KHz Pre Amp Out Total...

Page 22: ...ASS TREBLE MIC1 MIC2 MIC3 AUX1 AUX2 TEL MASTER POWER 2 PROT TEMP 4 6 8 10 12 OUTPUT LEVEL MIC2 MIC3 MUTE G TEL INPUT AUX2 AUX1 LINE OUT MIC 1 XLR 6 30 INPUT BAL UNBAL PHANTOM OUTPUTS COM 4 16 70V 100V...

Page 23: ...Version V0 1 PROFESSIONAL PUBLIC ADDRESS SYSTEM...

Reviews: