background image

ELSA DASH/SPRINT 

11 

 

 

7. 

Check that the cylinder contents 

gauge shows fully charged and screw 

the reducer into the cylinder valve. 

 

8. 

Fit the cylinder into the bag and 

arrange the contents gauge so that it 

can  be  seen  clearly  when  the  bag  is 

closed.  Secure  the  cylinder  with  the 

retaining strap and buckle. 
9. 

Feed the breathing hose into the 

bag. 
10.  Arrange the hood in the bag so 

that  it  will  not  foul  when  pulled  from 

the bag. 
11.  Check that the quick-fire cord is 

in good condition. 

 

 

12.  Wind the quick fire cord around 

the cylinder valve handwheel, so that 

the  handwheel  turns  anti-clockwise 

when the cord is pulled. 
13.  Close the bag lid and fit an anti-

tamper tag. 

4.4  BREATHING APPARATUS 

LOG 

Enter  details  of  the  results  of  the 

preceding  tests  in  the  appropriate 

breathing  apparatus  log.  A  breathing 

apparatus log is available from 

Scott

 

Health  and  Safety  Limited

  under 

Article Number 1034745. 

4.5  STOW APPARATUS 

Apparatus  should  be  stored,  or 

stowed  ready  for  use,  away  from 

direct  sunlight  (which  will,  through 

time,  degrade  the  material  of  the 

bag). 
Apparatus  stored  in  temperatures 

below  +4ºC  must  be  thoroughly  dry 

prior to storage and must be kept dry, 

as ice forming on or in the apparatus 

may degrade performance. 

Summary of Contents for ELSA Sprint

Page 1: ...ELSA DASH SPRINT Compressed Air Escape Breathing Apparatus User Instructions Article No 1034931 Issue F 03 2003...

Page 2: ...RINT 5 2 7 STORAGE BAG 5 2 8 QUALITY ATTRIBUTES 6 3 INSTRUCTIONS FOR USE 6 3 1 INITIAL CHECKS 6 3 2 DONNING 6 3 3 HOOD DASH SPRINT 7 3 4 FACEMASK SPRINT 8 4 AFTER USE CLEANING AND TESTING 9 4 1 CLEANI...

Page 3: ...daily when issued to wearers or deployed in ready use lockers or monthly if held in stores ELSA Dash and Sprint are escape apparatus DO NOT use for other purposes such as fire fighting or cargo handl...

Page 4: ...3 for 200 bar cylinders or 35 mg m 3 for 300 bar cylinders National regulations for compressed air breathing apparatus must be observed 1 2 APPARATUS SELECTION When selecting respiratory protective eq...

Page 5: ...e Manuals there are no shelf life limitations 1 6 USE IN EXPLOSIVE OR FLAMMABLE ATMOSPHERES Anti static versions of ELSA apparatus are approved for use in explosive and flammable atmospheres Anti stat...

Page 6: ...easily when the bag is opened provides an indication that the bag has been opened When the apparatus is first delivered tags are provided separately with instructions for fitting permitting the conten...

Page 7: ...SKS SPRINT Sprint is available with PanaSeal or Vision 3 facemasks Both are moulded in non dermatitic material and can be supplied with five point elastic or Neoprene head harnesses PanaSeal Facemask...

Page 8: ...ed closes the demand valve This permits the demand valve to be removed from the facepiece for testing or at the end of an escape Once reset the demand valve is opened by the wearer inhaling sharply 2...

Page 9: ...pparatus is an ISO9001 BS 5750 Pt 1 approved Division of Scott Health and Safety Limited NOTIFIED BODY Inspec International Ltd No 0194 Upper Wingbury Courtyard Wingrave Aylesbury Buckinghamshire HP22...

Page 10: ...open the valve Cautions Ensure that finger nails and rings do not snag or tear the neckseal Do not roll or fold the neckseal when donning the hood 3 3 HOOD DASH SPRINT 1 Pull out the hood insert hands...

Page 11: ...rness over the head If a Neoprene head harness is fitted tighten the straps in sequence bottom side then top DO NOT OVER TIGHTEN as this distorts the faceseal causing leaks 3 Inhale sharply to activat...

Page 12: ...od breathing hose and bag using a clean lint free cloth moistened in a solution of TriGene Article Numbers 2008247 for 1 litre or 2008248 for 5 litres and warm water 4 Allow the hood and bag to dry na...

Page 13: ...unlight and direct heat 5 Disinfect the faceseal and inner mask with a TriGene hygienic wipe 6 Use an Exxene de misting wipe to polish the visor 7 Check the demand valve locking catch moves freely wit...

Page 14: ...rd around the cylinder valve handwheel so that the handwheel turns anti clockwise when the cord is pulled 13 Close the bag lid and fit an anti tamper tag 4 4 BREATHING APPARATUS LOG Enter details of t...

Page 15: ...is a mandatory requirement that all escape apparatus shall be checked at monthly intervals In addition apparatus issued to wearers should be checked when issued and daily thereafter Apparatus deploye...

Page 16: ...that the red O ring on the elbow is in good condition Replace if worn damaged or contaminated with oil or grease 4 Check that the silencer filter is not clogged worn or damaged Replace if necessary 5...

Page 17: ...panels of the hood 2 Push the top of the hood into the bag with the rear hood panel next to the cylinder until the exhale valve is just below the rim of the bag 3 Roll the neckseal under the hood so...

Page 18: ...Sabre Breathing Apparatus Scott Health and Safety Limited Pimbo Road West Pimbo Skelmersdale Lancashire WN8 9RA United Kingdom Tel 44 0 1695 711711 Fax 44 0 1695 711775...

Reviews: