 9. Now lower the master volume slightly so that the system

is not on the verge of another feedback point. This is the
maximum volume level that the FBX will be able to provide.
Higher levels will cause uncontrollable feedback.

10.  We recommend you press LOCK FIXED to lock the Fixed

filters at their current depth.  See the Features section
below for a complete explanation.

11. Channels A and B must be set individually and separately.

To set the second channel, turn down the volume for the first
channel, then bypass the first channel and repeat this
system initializing procedure.

12. You’re ready to go.  Make sure TURBO mode is off (clip LED

not flashing).  ClipGuard™ will automatically match the
input level to the best internal dynamic range.

How To Use FBX2020-Plus Features

Using the “LOCK FIXED” feature:
In rare situations the FBX may mistake music for feedback and
drive the fixed filters deeper than necessary, such as in a church
with a pipe organ or during a performance with a great deal of
intentional sustained electric guitar feedback.  You can prevent
the fixed filters from deepening beyond their preset depth by
pressing the “LOCK FIXED” button on the front panel.  The
“LOCK FIXED” LED will light to indicate that the FBX is in “LOCK
FIXED” mode.  The fixed filters will stay locked until you press
the “LOCK FIXED” button again.  The dynamic filters are not
affected.

Selecting filter width:
If you’re using the FBX for a music application, the standard 1/10-
octave constant “Q” filter is most effective.  However, in spoken
word applications, such as lectures or teleconferencing, we
recommend using the wider 1/5-octave filter for more robust
feedback control.  You may enable the 1/5-octave filters by
pressing the “FIFTH OCTAVE” button, and the built-in LED will
light.  Only filters set after pressing the button in will be 1/5-octave.
Press the button again to set subsequent filters to standard 1/10-
octave filters.

Important Operating Considerations

Memory:
The  FBX  stores the positions and depths of the filters in
nonvolatile internal memory when the unit is turned off or during
a power failure.  The unit will return all filters to their previous
frequencies and depths when it is turned back on.

Bypass Mode:
The FBX has a true power-off bypass. The signal is unaffected
in BYPASS MODE even if the unit is turned off. Please note that
if a combination of BALANCED and UNBALANCED inputs and
outputs is used, the signal may be disconnected or attenuated
in BYPASS MODE.

Resetting the filters:
You must reset the  FBX if the microphones or speakers are
moved significantly.  To reset the unit, place the PA system’s
master volume to minimum and then press the reset button until
all the FILTER LEDs stop flashing. Then follow the system
initialization procedure explained previously.  Or you can reset
only the Dynamic filters by pressing and releasing the reset
button after the Dynamic filter LEDs stop flashing.  This may be
useful in certain situations, for example, after extensive wireless
microphone use.

Reset Options
The Reset button has two functions:  You can reset all the FBX
filters, or just the Dynamic Filters.  Hold the reset button in and
all the filter LEDs will begin flashing.  To clear only the Dynamic
filters, release the Reset button when the Dynamic filter  LEDs
go off (after three flashes).  To clear all the filters, do not release
the Reset button until all the filters LEDs go off.  A full reset is
recommended whenever you change speaker or microphone
positions.  NOTE:  Factory default is 9 Fixed and 3 Dynamic
filters, so if you reset Dynamics only those three lights will go
out during reset.  And remember, whenever you perform a full
reset you will automatically be in TURBO mode.

 WARNING: 

 

Do not reset all filters during the program.  This

releases all the feedback you eliminated during setup.  

Use

extreme caution when resetting the Dynamic filters, because
you may need those filters at that moment during the show.

How To Operate The FBX2020-Plus

Follow these steps to obtain the maximum gain before feed-
back without changing the tonal quality of your program.
(Important note:  Set up only one channel at a time.  Do not
attempt to ring out both channels of your sound system for
feedback simultaneously.)

1

1. Place the speakers and microphones in the positions

where they will be used during the program. Avoid placing
microphones directly in front of speakers.

1

2. Place both FBX channels in BYPASS mode.

1

3. Set the mixer's master volume controls to their lowest

positions. Turn on the mixer, then the FBX, then any other
accessories and finally the power amp. If you are using a
graphic EQ, adjust only for the desired tonal qualities, but
DO NOT NOTCH FOR FEEDBACK. Adjust the balance for
each mixer channel, and set the sound system’s master
volume to minimum.

1

4. Press RESET for 3 LED flashes to clear dynamic filters, and

an additional 4 flashes to clear ALL filters set previously.

  5. OPTIONAL:  

Set the total number of FBX filters.

   (Factory

default is 12 filters per channel - skip to #7 if default is OK
for your application)  You can limit the number of available
FBX filters.  Hold down the SET TOTAL NO. button for 4
seconds.  The LEDs will flash 4 times.  Release the SET
TOTAL NO. button.  The LEDs will begin to light in se-
quence.  When the LED corresponding to the desired
number of filters lights, press the SET TOTAL NO. button.
You've successfully set the total number of filters.

 6. OPTIONAL:  Set the number of Fixed filters (Factory default

is 9 fixed and 3 dynamic per chan-
nel - skip to #7 if default is OK for
your application).   Depress the
SET FIXED button for 4 seconds.
The filters LEDs will flash 4 times
and then go out.  Release the SET
FIXED button, and the LEDs will
begin to light in sequence.  When
the LED corresponding to the de-
sired number of Fixed filters lights,

press the SET FIXED button.  You’ve successfully set the
number of fixed filters.  The remaining filters will be your
dynamic filters.

 7.  Press the Bypass button to put the FBX in active mode for

the channel you want to set (red LED off).

 8. Slowly raise the sound system’s master volume for the

channel being set until feedback occurs. The  FBX will
quickly remove the feedback. The first FILTER LED will then
blink to indicate a filter has been set. Repeat this procedure
until all of the FIXED FILTERS and one of the DYNAMIC
FILTERS are set.  TURBO setup mode goes off automati-
cally.

IMPORTANT TIP:

You can mix 1/10- and 1/5-
octave filters in the same
channel. If you have an espe-
cially bad feedback problem,
try making the first few filters
1/5-octave and the remain-
ing filters 1/10-octave.

Summary of Contents for FBX 2020 Plus

Page 1: ...ndard FBX features such as lockable fixed filters and switchable 1 10 and 1 5 octave constant Q filters are also included CONGRATULATIONS You now have the state of the art in feedback control Your Sabine FBX2020 Plus Dual Feedback Exterminator a dual channel 20 bit digital filtering device that gives you automatic real time feedback control and increases the clarity and volume of your system The F...

Page 2: ...the program Second the FBX micro filters are precisely placed while EQ filters are fixed The difference FBX filters do not have to be as deep or wide so there is more system gain The third most important advantage is that FBX micro filters are ten times narrower than 31 band EQ filters FBX micro filters return up to 90 percent of the power removed by EQ filters Over the years engineers stopped usi...

Page 3: ... s filters is activated the corresponding LED lights A blinking LED indicates the filter that was most recently activated POWERSWITCH The ON OFF switch is a two position push button switch The power indicator LED will light when the FBX is operational SETTOTALNO To set the total number of filters depress the button for 4 seconds and then release The LEDs will begin to light in sequence When the LE...

Page 4: ...OUT CHB IN CHA IN CHA IN CHB IN FBX SET UP FOR ENTIRE MIX APPLICATIONS CHB OUT CHA OUT CHA OUT AMP AMP Mix 1 Mix 2 MIXER All other signal processing equipment All other signal processing equipment AMP AMP Right Send Left Send MIXER ...

Page 5: ...t Channel 1 HIGH Z LOW Z INSERT RETURN INSERT SEND HIGH Z LOW Z INSERT RETURN INSERT SEND FBX SET UP FOR SINGLE INSERT POINT CHA OUT CHA IN CHB OUT CHB IN FBX SET UP FOR INSERT SEND RETURN MIXER Input Channel 2 HIGH Z LOW Z INSERT MIXER Input Channel 1 HIGH Z LOW Z INSERT Insert Y cord 1 4 TS plug R 1 4 TS plug T 1 4 TRS plug CHB OUT CHB IN CHA IN CHA OUT ...

Page 6: ...al dynamic range to the constantly changing pro gram level and maintains unity gain ClipGuard extends the effective dynamic range of your FBX2020 Plus from 100dB to 105dB OPERATING INSTRUCTIONS ClipGuard incorporates TURBO mode setup another new feature It cuts the time for FBX filter initialization to just a few seconds and it greatly reduces the volume level of the feed back during setup The FBX...

Page 7: ...EDs will begin flashing To clear only the Dynamic filters release the Reset button when the Dynamic filter LEDs go off after three flashes To clear all the filters do not release the Reset button until all the filters LEDs go off A full reset is recommended whenever you change speaker or microphone positions NOTE Factory default is 9 Fixed and 3 Dynamic filters so if you reset Dynamics only those ...

Page 8: ... is set so that all of the signal is routed completely through the effects loop You cannot mix dry signal with effects signal and still control feedback Q The signal input LEDs do not light The unit will not catch feedback Why A The unit is not in the signal path Check the connections Be sure that the program is interrupted when the input is discon nected from the back of the unit Q Can I mix bala...

Page 9: ...Adjustment Automatic Clip Level Adjustment TRS TRS INPUT OUTPUT FBX 2020Plus SIMPLIFIED INTERNAL BLOCK DIAGRAM Analog Digital Converter Digital Analog Converter XLR 1 3 2 XLR 1 3 2 PERFORMANCE Spectral Variation 25 dB 20Hz to 20 KHz SNR 100 dB typical A weighted THD 0 02 22 dBV sine wave at 1 KHz Dynamic Range 105 dB with ClipGuard automatic clip level control active POWER INPUT Factory configured...

Page 10: ...abilitywillnotapplytoclaimsforpersonal injury or damage to real property or tangible personal property allegedly caused by Sabine s negligence Sabinedoesnotassumeliabilityforpersonalinjuryorpropertydamagearisingout oforcausedbyanon Sabinealterationorattachment nordoesSabineassumeanyresponsibility fordamagetointerconnectednon Sabineequipmentthatmayresultfromthenormalfunctioning andmaintenanceoftheS...

Page 11: ...into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Canadian Compliance Statement This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regula tions of the Canadian Department of Communications Le present appareil nu...

Page 12: ...N USA MADE IN USA MADE IN USA MADE IN USA Manufactured by Sabine Inc 13301 NW US Highway 441 Alachua Florida 32615 8544 USA Phone 386 418 2000 Fax 386 418 2001 www Sabine com Register your FBX2020 Plus online at Sabine com ...

Reviews: