SABINE FBX-1020 Operating Manual Download Page 4

4

FBX-1020 CONTROLS

A/C Power Input

The FBX-1020 is factory configured to operate at either 115 VAC
or 230 VAC. Using the wrong input voltage may cause perma-
nent damage to the unit and will void the warranty.

Audio Inputs & Outputs

1/4" TRS and XLR balanced and unbalanced.

Active/Bypass Switch

Bypass mode takes the unit out of the signal path so that it will
have no effect on the program. In active mode, the unit controls
feedback automatically. The red BYPASS LED lights when the
unit is in bypass mode.

Signal Level

The LED ladder indicates the signal strength relative to the
FBX's input clip level. The red CLIP LED indicates clipping; it
also indicates the unit is in TURBO mode.

Reset

 To reset ALL filters, hold the reset button for 4 seconds until all
filter LEDs are off.

Set Total Number of Filters

To set the total number of filters, depress the button for 4
seconds and then release.  The LEDs will begin to light in
sequence.  When the LED corresponding to the desired
number of filters lights, press the button to register your
selection.

Set Fixed

To set fixed filters, hold down the button for 4 seconds and then
release.  The LEDs will begin to light in sequence.  When the
LED corresponding to the desired number of fixed filters lights,
press the button to register your selection. (Factory default is
nine fixed and three dynamic filters.)

Lock Fixed Filters

When the LOCK FIXED button is pressed, its LED will light to
indicate that the FBX is in LOCK FIXED mode.  LOCK FIXED
mode can be activated at any time after system setup and will
stay on until the button is pressed again and the LED turns off.
Engaging the LOCK FIXED button also takes the FBX-1020 out
of ClipGuard's TURBO setup mode.

Fifth Octave

Press the button at any time to select wider filters for any new
filters to be set.  It is possible to have both 1/5 and 1/10 octave
Constant Q filters active in one channel simultaneously.

Filter Stage Activity

When one of the unit’s 10 filters is activated, the corresponding
LED lights.  A blinking LED indicates the filter that was most
recently activated.

Power Switch

The ON/OFF switch is a two-position push button switch. The
power indicator LED will light when the FBX is operational.

FBX-1020 Front Panel

FBX-1020 Back Panel

Fuse

This equipment is fitted with an IEC power inlet incorporating
a built-in fuse holder.  To change the fuse in this socket:

1. Disconnect the power cord from the unit.

2. Pull out the fuse holder and remove the old fuse.

3. Install the new fuse into the holder. Replace only with

5x20mm, 0.315A, 250V F (fast acting) fuse.

4. Refit the fuse cover.

Summary of Contents for FBX-1020

Page 1: ...ROLS 4 LOCK FIXED FILTERS 4 FIFTH OCTAVE 4 FILTER STAGE ACTIVITY 4 POWER SWITCH 4 FUSE 4 APPLICATION DIAGRAMS 5 FBX SETUP FOR MONITORS 5 FBX SETUP FOR ENTIRE MIX 5 FBX 1020 OPERATING INSTRUCTIONS 6 WH...

Page 2: ...rer s Name Sabine Inc Manufacturer s Address 13301 Highway 441 Alachua FL 32615 8544 USA Type of Equipment Equalizer Model No FBX 1020 Serial No Year of Manufacture 1997 and on I the undersigned herby...

Page 3: ...nce FBX filters do not have to be as deep so there is more system gain The most important advantage is that FBX micro filters are ten times narrower than 31 band EQ filters FBX micro filters return up...

Page 4: ...g to the desired number of fixed filters lights press the button to register your selection Factory default is nine fixed and three dynamic filters Lock Fixed Filters When the LOCK FIXED button is pre...

Page 5: ...5 APPLICATION DIAGRAMS FBX Setup for Entire Mix FBX OUT Main OUT FBX IN Amp IN Amplifier All other Signal Processing Equipment FBX Setup for Monitors Monitor OUT FBX IN FBX Out Amp In Amplifier...

Page 6: ...ault ClipGuard Adaptive Clip Level Control Your FBX 1020 has a powerful new feature Sabine s patented ClipGuard adaptive clip level control Until Sabine invented ClipGuard engineers had to set audio e...

Page 7: ...initialize for feedback Remember if you leave LOCK FIXED on the fixed filters won t initialize The LED indicating LOCK FIXED should be off when initial izing How To Operate The FBX 1020 Follow these...

Page 8: ...for FBX filter initialization to just a few seconds and it reduces the volume level of the feedback during setup The 1020 is set in TURBO mode at the factory and automatically engages every time you p...

Page 9: ...rops significantly below 10 of the specified voltage Check the A C power mains Q Why does my system sound thin and muffled A Place the FBX in BYPASS MODE If the system still sounds thin your problem i...

Page 10: ...3 and 1 4 TRS PERFORMANCE3 Spectral Variation 25 dB 20Hz to 20 KHz SNR 100 dB typical A weighted NOTES 1 Below approximately 200 Hz the feedback filters become slightly wider to increase the feedback...

Page 11: ...the dealer or an experienced radio TV technician for help Canadian Compliance Statement This digital apparatus does not exceed the Class B limits for radio noise emissionsfromdigitalapparatussetoutint...

Page 12: ...illnotapplytoclaimsforpersonal injury or damage to real property or tangible personal property allegedly caused by Sabine s negli gence Sabine does not assume liability for personal injury or property...