CHECK FAULT

Faults

Resolvable Methods

1.Switch indicator is on, fan is

not working and control knob

is out of work.

1. Over voltage protection is

working. Close machine then open it

again after several minutes.

2.Switch indicator is lit and fan

is working. However, press

control knob of torch, there is

no HF arc-striking sound and

electromagnetic valve is not

working.

1. Check if torch is open cicuit.
2. Check if control knob of torch is

damaged.
3. Part of assistant power of top

board is damaged and there is no

DC 24v output.

3.Switch indicator is lit and fan

is working. However, press

control knob of torch, there is

no HF arc-striking sound and

inter red diode is lit.

1. Check if MOSFET of top board is

damaged (driver mould is

damaged).
2 .Rising transformer of bottom

board is damaged.
3. Control mould is damaged.

4.Switch indicator is lit and fan

and electromagnetic valve are

working. However, there is no

sound of HF arc-striking and

inter red diode is not lit.

There is some trouble in part of arc-

striking, such as:
1. It is too far between discharge tip

or there is adhesion in discharge tip.
2. Primary coil of arc-striking

transformer is damaged or poor

contact.
3. Check if four times voltage

rectifier diode is stricken.
4. Check if HF electric capacity

102/10KV is leaking.
Relay is damaged.

5.Other of machine is normal,

but arc is not be stricken when

it is be operating.

1.Input voltage is too low.
2.Pressure of air compressor is too

high or too low.

Summary of Contents for CUT50

Page 1: ...INVERTER PLASMA CUTTER OWNER S MANUAL MODEL CUT50 POWER IGBT CONTROLIED DC WELDING POWER SOU Website https s7 welder myshopify com Facebook email holafrank2014 outlook com...

Page 2: ...characteristics of cutting machine series Inverter cutting machine is developed that is given praise of revolution of cutting field by specialist Piloting arc system can strike arc easily with princi...

Page 3: ...ase 110V 15 Single phase 220V 15 Rate input Power KVA 7 6 4 2 No load voltage v 240 5 240 5 Rate output current A 40 50 Rate output voltage V 94V 96V Duty cycle 60 60 Burner inter Diameter mm 0 8 1 0...

Page 4: ...3 OPERATION AND INSTALLATION DIAGRAM...

Page 5: ...ve terminal of front panel then tighren it 3 Make sure air plug of torch is connected to switch connector of panel If it is arc supporting cutter arc supporting cable of torch is connected to terminal...

Page 6: ...natural wind is not satisfy to cool down components there are two axial flow fan in inter machine in order to force to cool down it NOTES Exhaust shutter must not in block or covered it is 0 3 m from...

Page 7: ...upporting user may be get rid of oxidized film of inter electrode by abrasive paper Then machine will be operated normally MAINTENANCE AND CHECK TROUBLE Maintenance 1 Remove dust by compressed air reg...

Page 8: ...c striking sound and inter red diode is lit 1 Check if MOSFET of top board is damaged driver mould is damaged 2 Rising transformer of bottom board is damaged 3 Control mould is damaged 4 Switch indica...

Reviews: