RS485 and RS422 line terminator resistor
MULTI DROP connections, like RS485 and RS422, require having a resistance applied at both ends of the communication line
(if not yet present inside the connected devices); one is to be placed in parallel to the last AN401
plus
and one on the PLC or
computer on the other end.
AN401
plus
has no internal resistance for RS485 or RS422 but It can be applied under customer’s request.
This resistor has to be 120 Ohm ¼ Watt.
This resistance is to be applied solely on the last AN401
plus
of the serial net, in order not to lower, too much, the overall line
impedance (fig.11).