S2P KS2P-18C210 Owner'S Manual Download Page 7

Evaporative Air Cooler 

 

Packing and transportation 

1.  Packed in carton on wood pallet.  

2.  Keep dry and upright.  

3.  Do not pile more than 2 units. 

4.  Keep the  unit  vertical during transportation. The tilt angle shall be less than 60 degrees.   

 

Operating Instructions  

Installing the casters:

 

 

Locate the casters inside of the cooler and attach them to the cabinet bottom.  Start all bolts into nuts before 

tightening. The rigid casters mount at the front and the swivel casters  mount at the back.  

 

Connecting the water: 

Move  the  cooler  to  an  area  where  it  can  be  filled  with  water  and  drained.  The  cooler  should  be  located  on 

level  ground.  Connect  to  a  water  supply  using  a  commercial  grade  garden  hose  connected  to  the  adapter 

on  the  float  valve  and  turn  on  the  water.  Verify  water  tight  connections  by  visually  examining  both  the 

float/hose connection and drain  plug.     

 

Turn  on  the  water  supply  to  the  cooler.  The  hose  connection  to  the  float  valve  provides  an  automatic 

method  of refilling the water supply as water is evaporated.  

For  best  results,  turn  the  pump  on  a  few  minutes  before  turning  on  the  blower  fan.  This  allows  the  cooling 

pads to pre-wet best efficiency. 

 

Whenever possible  operate the blower fan at low speed  for maximum cool ing. When cooling is not required 

you can operate the unit as a fan only by turning on the blower fan and leaving the pump turned off.  

The  water can  be  adjusted by tightening  of loosening the clamp that pinches the  water supply tube.  Adjust 

the water  flow clamp so that adequate  water is supplied to t he as pen  pads without excess wat er splashing 

out of the trough during normal  operation. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for KS2P-18C210

Page 1: ...setting up and operating this unit This manual is designed to provide you with important information needed to setup operate maintain and troubleshoot your cooler Failure to follow these instructions...

Page 2: ...n evaporative cooler a circulation pump keeps the cellulose filter pads fully soaked As warm air passes over wet filter pads water naturally evaporates into the air The air is cooled as it gives up th...

Page 3: ...Well designed system ensures best cooling effect 2 Energy efficient and environmental friendly saving more than 80 of electricity as compare with conventional compressor air conditioners 3 The patent...

Page 4: ...ic cleaning and drainage functions keep the evaporative air coolers blow fresh and cool air Water level probe Water level control Precisely and accurately checks the water level Device to prevent dama...

Page 5: ...ing every 8hours Prevents algae growth Maintains clean unit Clean and dry function Inlet valve New type smart designed permanent magnetic valve Small buoy unsurpassed reliability Circulation water pum...

Page 6: ...aust the designed exhaust volume shall not be less than 85 of air intake 4 Keep the unit away from welding sparks or any source of fire during the installation and when the unit is running 5 The unit...

Page 7: ...dapter on the float valve and turn on the water Verify water tight connections by visually examining both the float hose connection and drain plug Turn on the water supply to the cooler The hose conne...

Page 8: ...actory setting restart 2 SETTING THE CLOCK Set the clock on the wall controller before proceeding with any other programs The picture of 2 1 the current time is 12 00 The setting as follows 1 Press th...

Page 9: ...cted the wall controller will maintain a constant fan speed To increase or decrease the fan speed required press the buttons Note in order to protect motor when the VENT function been switched to EXHA...

Page 10: ...minutes will stop automatically When draining the water level will decline rapidly so if the COOL function is still keep on the pump will pause automatically to protect pump and running again when DRA...

Page 11: ...ns on under FAN and COOL functions work together Picture 6 1 Auto cleaning cycle is 08 hour 7 SWING Note if there is no electronic swing air diffuser this function will not available Swing function me...

Page 12: ...and the hour is flashing use button to changes hour like the picture of 8 2 3 Then Press button the hour stop blinking the minute is flashing use button to changes minutes like the picture of 8 3 4 Pr...

Page 13: ...n Press button change to 00 00 the hour is blinking press button to change hours like the picture of 8 7 4 Press button the hour stop blinking the minute is flashing press button to change minutes lik...

Page 14: ...ee the picture of 8 5 2 Press button the screen shows 23 30 OFF is flashing time of turn off is 23 30 see the picture of 8 10 3 Then Press button the screen shows ON and OFF is flashing timing been ca...

Page 15: ...emperature control does not support the humidity control press button for 3 seconds can switch air cooler s working modes that is MANUAL AUTO AUTO 9 1 MANUAL MODE With the wall controller on press the...

Page 16: ...e on AUTO mode is 25 if want to change press button the preconcerted temperature will flash as shown in picture 9 4 button will change the preconcerted temperature press button again the setting is fi...

Page 17: ...mperature will flash as shown in picture 9 7 use buttons to change press button again the setting been finished as shown in picture 9 8 The relative humidity has been change to 57 Picture 9 6 AUTO mod...

Page 18: ...r turned off Note 2 The settings on PRE COOLING mode will be stored automatically and continue to use in next reboot Picture 10 1 Turn on PRE COOLING mode Picture 10 2 Turn off PRE COOLING mode Picute...

Page 19: ...tinue to use in next reboot Picture 11 1 Turn on INTELLIGENT Picture11 2 Turn on INTELLIGENT CLEANING MODE CLEANING MODE 12 SHUTDOWN CLEANING MODE Note If your wall controller is designed to shutdown...

Page 20: ...ASHING When the FAN icon flashing as shown in picture 10 3 that means the air cooler is pre cooling pump works for 1 minute the FAN will be opened automatically If the water level is too low will wate...

Page 21: ...ten to keep the cooling efficient Do not use water above 40 Banister brush can be used softly to scrub away the dust on the pads 3 The water supply should be shut off to avoid bacteria as well as cold...

Page 22: ...uit Fan motor control relay failure Replace the relay When replace note the current capacity and pressure 4 Pump indicator flash and the cooling efficiency is not good Water supply system failure not...

Page 23: ...ore air than required Adjust any beffles or balance flow to reduce airflow Ducting is too small and the velocity is too quick Replace the ducting 10 Water being thrown into the area being cooled Old f...

Page 24: ...the part or mileage allowance to or from the site S2P does not pay freight or postage on any exchange Do not use cooler cleaner cooler treatments or other additives in this evaporative cooler The use...