background image

 

- 2 - 

CONTENTS OF THIS MANUAL 

1….  GENERAL DESCRIPTION

 

2….  SPECIFICATIONS 
3….  RECOMMENDED LOCATIONS OF DETECTORS 
4….  LOCATIONS TO AVOID 
5….  CHEMICALS TO AVOID 
6….  INSTALLATION INSTRUCTIONS 
7….  OPERATION AND TESTING 
8….  FALSE ALARMS 
9….  MAINTENANCE 
10…  LIMITATIONS OF NATURAL (METHANE) GAS DETECTORS 
11…  GOOD SAFETY HABITS 
12…  SERVICE AND WARRANTY 
 

WARNING!  

DISCONNECTING OR LOSS OF  AC POWER (OR DC POWER IN 

MODEL PSM-011)  WILL RENDER THIS UNIT INOPERATIVE.

 

 
 

1.  GENERAL DESCRIPTION

 

The  natural  (methane)  gas  detector  provides  an  early  residential  warning  of  the 
presence  of  explosive  natural  (methane)  gas  and  is  factory  calibrated  to  sound  an 
alarm  that  meets  UL1484  standard.    The  L.E.L.  (Lower  Explosive  Level)  of  natural 
(methane) gas is 5% in volume and the alarm level of this detector is set at 10 – 25% 
of the L.E.L. (Lower Explosive Level). 
When the alarm is triggered the red light and buzzer will stay on for a minimum of 5 
minutes.    If  natural  (methane)  gas  levels  persist  beyond  the  calibrated  level,  the 
detector  will  continue  to  alarm  until  the  natural  (methane)  gas  is  cleared.    See 
OPERATION section for further information. 
There  have  been  many  cases  of  serious  injuries  and  damages  reported  that  were 
caused by natural (methane) gas leak explosions. 

 

IMPORTANT!

 

READ  ALL  OPERATION  INSTRUCTIONS  CAREFULLY.  

FAMILIARIZE  YOUR  FAMILY  WITH  THE  ALARM  SIGNAL  AND  WHAT  TO  DO  IN 
THE EVENT OF AN ALARM. 

Summary of Contents for STCH-1000

Page 1: ... option ELECTRICAL RATING 120VAC 60Hz 5 Watts PSM 011 Natural Methane Gas Detector 12 VDC direct wire in with relay ELECTRICAL RATING 12VDC 5 Watts IMPORTANT READ ALL INSTRUCTIONS BEFORE INSTALLATION AND SAVE THIS MANUAL FOR FUTURE REFERENCE WARNING THIS DETECTOR WILL ONLY INDICATE THE PRESENCE OF NATURAL METHANE GAS AT THE SENSOR NATURAL METHANE GAS MAY BE PRESENT IN OTHER AREAS THIS DEVICE IS NO...

Page 2: ...d is factory calibrated to sound an alarm that meets UL1484 standard The L E L Lower Explosive Level of natural methane gas is 5 in volume and the alarm level of this detector is set at 10 25 of the L E L Lower Explosive Level When the alarm is triggered the red light and buzzer will stay on for a minimum of 5 minutes If natural methane gas levels persist beyond the calibrated level the detector w...

Page 3: ...hat gas operated appliances are installed see Figure 1 Since natural methane gas is lighter than air 1 0 56 the greatest concentration of gas will be immediately under the ceiling Mount detectors on the wall with the top edge of the detector at a minimum of 6 15cm and a maximum of 12 30 5 cm below the ceiling and at least 2 feet 60 1 cm from any corner see Figure 2 If the ceiling is sloped or high...

Page 4: ...METALLIC COMPOUNDS FOUND IN SOME FUELS ACETYLENE FOUND IN OXY FUEL WELDING 6 INSTALLATION INSTRUCTIONS NOTE REVIEW SECTION 3 RECOMMENDED LOCATIONS OF DETECTORS AND SECTION 4 LOCATIONS TO AVOID PRIOR TO INSTALLING YOUR DETECTOR The proper power for the STCH 1000 series natural methane gas detectors is 120 volt single phase supplied from a non switchable circuit which is not protected by a ground fa...

Page 5: ...he black wire is connected to 120VAC Hot line and the white wire is connected to the Neutral line see Figure 3A Installation of PSM 011 PSM 011 has two sets of wire harness DC power and relay For the DC Power Quick Connector wiring connection the red wire is connected to 12VDC and the black wire is connected to 0VDC see Figure 3B Connections on the relay The Relay Quick Connector has three wires t...

Page 6: ...et above the floor Pull the Quick Connector through the center hole in the mounting plate Plug the mating halves of Quick Connector with the same color of wires together Slide the detector on the mounting plate to the lock position Turn on the power and the green POWER ON indicator should be lit for receiving power After installation TEST your detector by pressing and holding the TEST RESET button...

Page 7: ...alibrated level 10 25 L E L the detector will sound beep beep and turn on the red LED If this dangerous condition lasts for 4 seconds the natural methane gas detector will latch on alarm mode for 5 minutes with the red LED turning on and the buzzer sounding continuously During this 5 minutes period the detector will cease sensing gas concentrations and the green LED will flash to indicate the same...

Page 8: ...y the Gas Company check to see if one of the reasons listed in section 4 may have caused the alarm Some solvents used in chemical cleaning agents paints varnishes and the furniture refinishing process and some propellants used in aerosol hair spray and air fresheners can cause the detector to alarm if they are used in close proximity to the detector for extended periods of time Gasoline or other f...

Page 9: ... methane gas STCH 1000 series A C powered detectors will not operate if the A C power has been cut off such as by an electrical fire a tripped circuit breaker or an open fuse These detectors must be tested regularly to make sure that they are receiving power and operating properly Detectors cannot sense natural methane gas that does not reach the detector and therefore detectors may not detect nat...

Page 10: ...m to leave your home when they hear it Practice an escape drill at least once every six months Practice allows you to test your plan before an emergency You may not be able to reach your children in an emergency so it is important that they know what to do b WHAT TO DO WHEN THE ALARM SOUNDS Leave immediately by your escape plan Every second counts so don t waste time getting dressed or picking up ...

Page 11: ...r if it fails to operate due to improper maintenance or inadequate A C D C electrical power THE LIABILITY OF PATRICK PLASTICS INC OR OF ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS ARISING FROM THE SALE OF THIS NATURAL METHANE GAS DETECTOR OR UNDER THE TERMS OF THIS LIMITED WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF THE REPLACEMENT OF THE NATURAL METHANE GAS DETECTOR IN NO CASE SHALL PATRIC...