D

  

Bedienungs- und Montageanleitung

Raum-Feuchte-, Temperatur- und CO

2

 - Fühler   

bzw. Messumformer, selbstkalibrierend,  
mit aktivem Ausgang

G

  

Operating Instructions, Mounting & Installation

Room humidity, temperature, and CO

2

 sensors  

and measuring transducers,  
self-calibrating with active output

F

  

Notice d’instruction

Sonde (transmetteur)  
d'humidité ambiante, de température et de CO

2

,  

auto-calibrante, avec sortie active

r

  

Руководство по монтажу и обслуживанию

Датчики  ⁄ измерительные преобразователи влажности,  
температуры и содержания СО

2

 для внутренних помещений,  

самокалибрующиеся, с активным выходом

RTM - CO

2

 - A

mit LED 

with LED 

avec DEL 

со светодиодами

RTM - CO

2

 - 2S

mit LED 

with LED 

avec DEL 

со светодиодами

RFTF - CO

2

 

RTM - CO

(Baldur 2 )

6002-8200-2011-000

  28200-2016  V100

    01  ⁄  2016

S+S REGELTECHNIK GMBH 
PIRNAER STRASSE 20 
90411 NÜRNBERG ⁄ GERMANY

FON  +49 (0) 911 ⁄ 5 19  47- 0 
FAX  +49 (0) 911 ⁄ 5 19  47- 70

[email protected] 
www.SplusS.de

Summary of Contents for RTM-CO2-2S

Page 1: ...vem Ausgang G Operating Instructions Mounting Installation Room humidity temperature and CO2 sensors and measuring transducers self calibrating with active output F Notice d instruction Sonde transmet...

Page 2: ...AERASGARD RFTF CO2 AERASGARD RTM CO2 D G F r Ma zeichnung Geh use Dimensional drawing Enclosure Plan cot bo tier Baldur2 T K 6 0 98 98 32 6...

Page 3: ...ufe 1 und 2 und AUS Ausgang CO2 0 10 V Messgenauigkeit CO2 70 ppm zzgl 5 vom Messwert Druckabh ngigkeit 1 6 kPa bezogen auf Normaldruck Langzeitstabilit t 1 EW Jahr Gasaustausch Diffusion TEMPERATUR M...

Page 4: ...Dieses Ger t darf nicht als sicherheitsrelevante Einrichtung verwendet werden ACHTUNG Die minimale CO2 Konzentration von Au enluft betr gt in begr nten industrie armen Gegenden ca 350ppm Ausgangs spa...

Page 5: ...r stetigen Verbesserung unserer Produkte m glich Bei Ver nderungen der Ger te durch den Anwender entfallen alle Gew hrleistungsanspr che Dieses Ger t darf nicht in der N he von W rmequellen z B Heizk...

Page 6: ...g accuracy CO2 70 ppm plus 5 of measured value Pressure dependence 1 6 kPa referred to standard pressure Long term stability 1 of final value per year Gas exchange by diffusion TEMPERATURE Measuring r...

Page 7: ...limit 1 0 ppm 1200 ppm 2 200 ppm 1400 ppm 3 400 ppm 1600 ppm 4 600 ppm 1800 ppm 5 800 ppm 2000 ppm S1 S2 5 3 4 2 1 5 3 4 2 1 S1 S2 5 3 4 2 1 5 3 4 2 1 ATTENTION The minimum CO2 concentration of outdo...

Page 8: ...in terms of technical progress and continuous improvement of our products In case of any modifications made by the user all warranty claims are forfeited This device must not be installed close to hea...

Page 9: ...nt peut tre chang par un bouton poussoir Automatique manuel degr s 1 et 2 et ARR T Sortie CO2 0 10 V Incertitude de mesure CO2 70 ppm 5 de la Vf D pendance de la pression 1 6 v MW kPa se r f rant la p...

Page 10: ...1400 ppm 3 400 ppm 1600 ppm 4 600 ppm 1800 ppm 5 800 ppm 2000 ppm S1 S2 5 3 4 2 1 5 3 4 2 1 S1 S2 5 3 4 2 1 5 3 4 2 1 ATTENTION La teneur minimale en CO2 de l air ext rieur dans des r gions vertes fai...

Page 11: ...de respecter les points suivants Avant de proc der toute installation et la mise en service veuillez lire attentivement la pr sente notice et toutes les consignes qui y sont pr cis es Les raccordemen...

Page 12: ...2004 108 EC 73 23 EEC RFTF CO2 RTM CO2 RTM CO2 A RTM CO2 2S 1 2 3 4 5 6 7 8 UB 24V AC DC UB GND GND GND GND Output 0 10V humidity in r H Output 0 10V temperature in C Output 0 10V CO2 content in ppm...

Page 13: ...M CO2 2S 0 2000 1 5 40 C 0 10 3 2 1501 4112 1060 000 A 5 CO2 RTM CO2 2S CO2 RFTF CO2 RTM CO2 A CO2 1 500 1 2 500 800 1 800 1200 1 1 1200 1600 1 2 1600 1 RTM CO2 2S CO2 800 1 800 1200 1 1200 1 RTM CO2...

Page 14: ...B 15 36 UB GND 24 Circuitry Circuitry 0 10V 0V GND 0 10V 0V GND Power supply AC 24V 0V DC 15 36V GND Circuitry 0 10V 0V GND V Power supply AC 24V 0V DC 15 36V GND r 10 95 0 50 C 7 300 400 ppm 10 7 ZVE...

Page 15: ...lift up the bottom frame slightly Pull top cover forward and hold it Pour ouvrir le bo tier placer le tournevis 2 0 au centre de l encoche pousser vers le bas et soulever l g rement le cadre inf rieu...

Page 16: ...ASGARD RTM CO2 Ma zeichnung Geh use Edelstahl Dimensional drawing Enclosure stainless steel Plan cot bo tier acier inox RTM CO2 Edelstahlgeh use stainless steel enclosure bo tier acier inox 6 0 100 97...

Reviews: