background image

 

 

G.  Set Up Reader Number Linked Through RS-485 

 

         

  

  

HW-5056  FUN:14 

 

              

LN485:****** 

   
 

 

Set up the reader number 

 

Input 14 and press ENT 

 

Input the model number from 000000-999999, then press ENT 

 

Press 

CLS

 to exit. 

 

H.  Delete All Learned Cards 

 

             

HW-5056  FUN:60 

 

             

22111000  WAIT 

 

 

 

The function delete all cards in the reader at once 

 

Input 60 and press ENT 

 

If the deletion is not successful or not enough memory, on the LCD, it will 
show ERROR and leave the Function set up menu automatically.  

 

If it’s completed, it will show SETOK 

 

Press 

CLS

 to exit. 

 

I.  To Delete All Records

 

 

            

HW-5056  FUN:61 

 

                  

SETOK    

 

 

This function delete all records in the reader at once 

 

Input 61 and press ENT 

 

If the deletion is not successful or not enough memory, on the LCD, it will 
show ERROR and leave the Function set up menu automatically.  

 

If it’s completed, it will show SETOK 

 

Press 

CLS

 to exit. 

 
 

Summary of Contents for HW-5056

Page 1: ...1 HW 5056 HW 5088 Proximity Reader User s Manual LCD SCREEN 1 2 3 ON 4 5 6 OFF 7 8 9 CLS 0 ENT ...

Page 2: ... press OFF and enter a new 4 digits PIN code The LCD will display as below after pressing OFF HW 5056 NEWCOD K When door is forced opened 1 If the reader detects that the door is opened without legal procedures it will activate the alarm that has been functioned 2 To relieve the alarm simply present a valid card to reader When Alarm is activated When the door is open through net work HW 5056 ALARM...

Page 3: ...ppear on the LCD The user has to enter the correct PIN code within 10 seconds in order to open the door If PIN code is not required the door will be opened after 1 to 4 seconds depends on the memory capacity of the reader After senor the LCD will show HW 5056 OPEN I Ender the password the LCD will show HW 5056 CODE I K I Card number K PIN code Enter the PIN code and press ENT If the code is incorr...

Page 4: ... door Input 01 and press ENT Enter any number between 1 and 255 and press ENT in seconds B Set up the Alarm Timing HW 5056 FUN 02 ARTMT 020 SEC To set the the length of alarming time when the alarm is activated Input 02 and press ENT Enter any number between 1 and 255 and press ENT in seconds Press CLS to exit C Set Up Alarm for Door Left Opened Overtime HW 5056 FUN 03 OVRTM 020 MIN If the door le...

Page 5: ...en 1 and 255 and press ENT in seconds Press CLS to exit The above four functions will not be in active if enter 0 E Set Up the Date HW 5056 FUN 10 DATE 02 00 01 This is to set up the date in the reader Input 10 and press ENT Input year month date Press CLS to exit F Set up the Time HW 5056 FUN 11 TIME 02 00 01 set up the time in the reader Input 10 and press ENT Input year month date Press CLS to ...

Page 6: ...d press ENT If the deletion is not successful or not enough memory on the LCD it will show ERROR and leave the Function set up menu automatically If it s completed it will show SETOK Press CLS to exit I To Delete All Records HW 5056 FUN 61 SETOK This function delete all records in the reader at once Input 61 and press ENT If the deletion is not successful or not enough memory on the LCD it will sh...

Page 7: ...ellow CON8 connect the other end of Magnetic Switch 3 If 1 2 functions are needed then JP2 and JP3 disconnect PIN yellow CON8 connect the other end of Magnetic Induction Switch PS JP1 on the PCB can adapt the open door connect output to NO or NC Weigand DATA 0 Weigand DATA1 Lock NO Alarm 12V Magnetic Switch NC Link to Computer DATA Link to Computer DATA Open Door With SW NO Lock Power DC12V 1A Rea...

Page 8: ... TO RS 485 CONVERTER PIN6 PIN1 The Transmissive distance is up to 1000M From converter to HW 388 3 The outlet of converter is PIN6 PIN1 From left to right PIN5 DATA Linked signal PIN4 DATA 4 6P BOX PHONE PIN5 DATA Connect to HW 5056 Brown Line DATA PIN4 DATA Connect to HW 5056 Green Line DATA PS In the middle PIN6 PIN5 PIN4 PIN6 PIN5 PIN4 PIN3 150O PIN2 Forward Resistance PIN1 PIN1 PIN2 PIN3 ...

Page 9: ...ber 1 from box Phone and from Number1 to Number 2 and to Number 3 B Avoiding to the meshed installation PC Output Port COM1 or COM2 HW 5056 Number 1 Brown Green HW 5056 Number 2 Brown Green RS232ßà RS485 Converter BOX PHONE PIN5 150Ω PIN4 BOX Phone Number 1 Number 2 Number 3 BOX Number1 Number Number ...

Page 10: ...to install in the line of latest HW 5056 èYou have to install two resistance 150 Ohm in the whole line 3 4P or 6P is available only Line 4 The output of PC port can changed by software 5 The line must use insulating line Please do not use the traditional line to avoid the bad transmission ...