S.R.Smith WPC1-T Series Installation Instructions Manual Download Page 1

WPC1-XXXX-T

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Installation Instructions

Read these instructions in their entirety before performing any installation work

FOR USE WITH POOL AND SPA PRODUCTS

4008814

ETL LISTED

Conforms to UL STD 379;

Certified to CSA STD C22.2 #218.1

79-15223-00 REV C1

Summary of Contents for WPC1-T Series

Page 1: ...VAC 60Hz applications Installation Instructions Read these instructions in their entirety before performing any installation work FOR USE WITH POOL AND SPA PRODUCTS 4008814 ETL LISTED Conforms to UL STD 379 Certified to CSA STD C22 2 218 1 79 15223 00 REV C1 ...

Page 2: ...2 ...

Page 3: ...or lighting use 6 Power Connection with GFCI 7 Hooking up Low Voltage Lights to Circuit 1 8 PUMP CONNECTIONS 9 Connecting A 240VAC Single Speed Pump 9 External Magnetic Antenna Mounting 10 OPERATING INSTRUCTIONS 11 Timer Operation 11 WPC 1 Toggle Switch Operation 12 Wireless Remote Operation 13 Wiring Diagram 14 Warranty Information 15 ...

Page 4: ... 12VAC 30 watt transformer Optional Accessory Part Description Not shown FP 1 2 Temperature Freeze Device Not shown PLX ANTKT L 15 meter magnetic mount antenna Kit ELECTRICAL RATINGS Do not exceed the maximum electrical ratings of the WPC 1 A circuit breaker rated at 20Amps at 120VAC must be installed in the breaker panel to connect to the WPC 1 power input Circuit 1 is rated for use of up to 2 5 ...

Page 5: ...es Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation 2 Changes or modifications not expressly approved by S R Smith could void the user s authority to operate the equipment WARNING TURN OFF INCOMING POWER BEFORE SERVICING EQUIPMENT AL...

Page 6: ...ke power connections remove inches of insulation from wire ends Insert the bare end of wires under the pressure plate of terminals Power Input HOT Use in flat head screwdriver to tighten terminal screws firmly 10 0 in lbs minimum Connect the house common to the Power Inputs NEUTRAL terminal Connect another HOT wire to the Timeclocks T C POWER terminal Connect a house common to the Timeclocks T C N...

Page 7: ...t the GROUND of the GFCI to the EQUIP GND bar Wire the HOT from the GFCI s LINE side to the 20Amp circuit breaker in the main breaker panel as discussed earlier Connect the NEUTRAL from the GFCI s LINE side to the house common From the GFCI s LINE side connect a wire from the HOT to the Timeclocks T C POWER terminal From the NEUTRAL of the LINE side on the GFCI connect to the T C NEUTRAL on the te...

Page 8: ...onvenient location to store service loop cable Use appropriate wire from the separate 12VAC output block to supply Low Voltage power from the WPC1 XXXX T to the approved Pull Junction or Bell Box Use the lower left knockout location s and be sure to replace the Isolation Cover using the grounding attachment screw Lastly use the supplied cable tie to secure the lighting wiring to the cover If this ...

Page 9: ...reaker for each pump if this control box is equipped with optional pump relays Using an appropriately sized copper wires connect to the outer contacts of the JQX relays of the appropriate pumps as shown Run wires from the pump to the inner contacts of the appropriate JQX relay NOTE This unit maybe equipped with more than one JQX relay for pump control 120V CIRCUIT BREAKER 240VAC PUMP GROUND ...

Page 10: ...e the antenna into a clear receiving zone While not required best range performance is found when the remote and the antenna are within line of sight and 100 or less NOTE The remote function of this device operates through radio frequency RF signals As with any RF device this is subject to interference through surroundings and installation location In the event of an interference issue or if longe...

Page 11: ...nce the time and time of operation has been set ensure that the Timer function switch is set to Auto for timer control of the Pump as illustrated below To turn off timers automatic functions set the Timer function switch to OFF To manually turn on the Pump set the Timer function switch to the ON position NOTE When in the ON position the Pump will continue to run until the Timer function switch is ...

Page 12: ...ll be disabled To re enable wireless remote operation flip the toggle switch back to the REMOTE position NOTE If a device turns ON when the toggle switch is set to the REMOTE position turn the wireless remote button OFF to turn off the device The toggle switches on the WPC 1 must be set to REMOTE for wireless operation The POWER ON OFF buttons control each circuit independently With each push of t...

Page 13: ...CHANGE to toggle on and off the power of Zone 2 on the WPC panel Color Changing Operation To change LED pool light colors simply toggle the power OFF then ON using the button marked 1 or 2 within 1 second Continue toggling until the desired color or light show is reached To operate both zones together simultaneously use the M master button on the remote NEW FEATURE 1 Button Color Sync Reset Operat...

Page 14: ...Y BK R BR BK 6 7 5 3 BK BR W R 1 2 8 4 BK W BK W BL BL CRIMP CONNECTORS 120V LINE NEUTRAL NEUTRAL CIRCUIT 2 12 VAC 12 VAC TC POWER TC NEUTRAL BK CIRCUIT 1 FOR USE ON WPC AUXILIARY RELAY KIT FOR TEMPERATURE FREEZE PROTECT SWITCH OPTION ...

Page 15: ...SWITCH 2 5 8 2 6 3 9 1 6 4 1 7 2 Y BK BR R 7 3 5 4 8 W O BK BK SWITCH 1 REMOTE ON COM ON COM M COM NO TIMER WARRANTY INFORMATION For Lighting product warranty information and details please visit our website www srsmith com warranty ...

Page 16: ...LC P O Box 400 Canby OR 97013 P 503 266 2231 TF 800 824 4387 srsmith com 2018 S R Smith All rights reserved 79 15223 00 REV C1 Questions Contact One of Our Dedicated Lighting Specialists 1 800 824 4387 x4012 or x2282 ...