www.srsmith.com
RM-6000 Remote Control System
INSTALLATION SHEET
This RM-6000 Automatic Operating
System package is specifically designed
Includes:
1) Transmitter
Antenna
for the 6004 AND 6004-AS fiber optic
illuminators and should not be modified or
adapted in any way. This is an electric
component and should only be installed
1) Receiver module with antenna
by a qualified technician.
Please follow the instructions carefully.
RANGE IS APPROXIMATELY 75 FEET
DEPENDING ON CONDITIONS.
1
Locate the 6 Pin Connector
DANGER: TURN OFF ELECTRIC SERVICE TO THE ILLUMINATOR FIRST!
Remove the two screws securing the cover and remove the cover. Inside the Lifetime Illuminator
TM
chassis is a 6-pin plastic connector. Locate the connector and unplug it. This is where the RM-6000
will connect.
2
Slide the RM-6000 into the chassis and plug it in
Slide the RM-6000 into the two slots on the left side of the chassis with the wires
facing the FRONT. Plug together the 6-pin connectors (note that the connectors
only fit together one way). Secure the wires in the chassis so the fan and color
wheel are not blocked. Take the single antenna wire and attach it to the top of the
illuminator chassis with a small piece of electrical tape.
3
Change the toggle switches
Replace the cover on the illuminator. Look at the toggle switch
label on the rear of the illuminator and move the toggle switches
to their correct position-
Power - bottom position
Color - middle position
Turn the power back on and test the unit for proper operation by
pressing the ON button for power, and the START button for color
wheel rotation.
4
Transmitter
Replacement Battery Type: Std. 9V
PM 10140 Rev. J3
COLOR WHEEL
POWER
Lamp "Restrike"
When turning the system off and then turning it
immediately back on, it may take 1 to 3 minutes
before the lamp comes back on.
This process allows the lamp to cool down and then
restart.
This is a normal function of the Metal-Halide lamp
system that the SR Smith 6000 Series illuminators
use.
This unit is equipped with an automatic 4 hour shut off.
It must be turned on with the transmitter after shut off.
TOGGLE SWITCH POSITIONS
OPTIONAL RM-6000 CONTROL
For multiple AS units, use WPC-1 or WPC-2 control system (sold separately)