CHARGEPLUS
Page 7 of
9
USERS MANUAL
FAULTS AND TROUBLESHOOTING
PROBLEMS
SOLUTIONS AND CHECKS
THE BATTERY CHARGER DOES NOT SWITCH ON.
CHECK THAT THE A/C AND D/C PLUGS ARE CONNECTED,
AND THAT THE A/C OUTLET IS RECEIVING POWER.
THE CHARGING CYCLE DOES NOT START AND THE
MESSAGE “bat” IS DISPLAYED.
CHECK THE CONNECTION TO THE BATTERY AND THE
POLARITY.
THE YELLOW INDICATOR (4) WILL NOT LIGHT UP EVEN
AFTER 15 HOURS FROM THE STARTING OF THE CHARGE
CYCLE, AND THE DISPLAY SHOWS “E03”.
CHECK THE BATTERY FOR POSSIBLE FAULTY
COMPONENTS.
THE MESSAGE “E01” IS DISPLAYED.
THE MAXIMUM VOLTAGE ADMISSIBLE BY THE BATTERY
HAS BEEN EXCEEDED. THE CHARGING IS
INTERRUPTED.
IF THE BATTERY CHARGER IS PROVIDED WITH A SAFETY
THERMOSTAT AND THE MESSAGE “E02” IS DISPLAYED.
THE MAXIMUM TEMPERATURE HAS BEEN EXCEEDED.
THE CHARGING IS INTERRUPTED.
THE MESSAGE “E03” IS DISPLAYED.
THE MAXIMUM TIME FOR THE CHARGING PHASE HAS
BEEN EXCEEDED. THE CHARGING IS INTERRUPTED.
THE MESSAGE “SCt” IS DISPLAYED.
THE TOTAL SAFETY TIMER HAS INTERRUPTED THE
CHARGING.
THE MESSAGE “Srt” IS DISPLAYED.
THERE IS A POSSIBLE INTERNAL SHORT CIRCUIT. THE
UNIT NEEDS TO BE SENT TO A REPAIR CENTER.