CLEANING & MAINTENANCE 

 
Changing or Cleaning the Filter / Pad: 
 
WARNING:    Unplug  and  disconnect  the  cooler  from  the  power  source 
before attempting any maintenance or service. 

 

Your cooler pads should be changed at least twice a year, at the beginning of a season and midway 
through.    But your pads may need to be changed more frequently, depending on local air and water 
conditions.    For instances, in areas where mineral content of the water is high, deposits may build 
up in the cooler pads, restricting air flow. 
 

Cleaning the Water Tank: 

 

To clean the water tank: 

  Remove the drain plug located at the bottom of the unit.   

  Once the water tank is empty, replace the drain plug, refill the unit and 

drain it again. 

  Repeat this cleaning weekly to reduce water mineral build up. 

  Replace the drain plug; refill with fresh water through water-inlet hose, 

cooler is ready for use. 

 
 
 
 

TIP:   
Regular  draining  (once  a  week  during  use)  will  decrease  the  water  mineral 
build up and extend the life of the filter / pad.    Damp a cloth with water and 
wipe  away  any  water  mineral  deposits  that  appear  inside  or  outside  the 
appliance to extend the serviceable life and clean appearance of the appliance. 

 

Cleaning the Appliance: 
 
Step 1: 

 
 
 
Screw  off  the  two  screws  at  the  top  of  the  cooling  pad.    Hold  the 
louver above the cooling pad, drag the cooling pad gently, and pull 
up slightly to put off the cooling pad for cleaning. 

 
 
 
 
Step 2: 
 
 

Summary of Contents for SO3500-JC

Page 1: ...ns carefully before setting up and operating this unit This manual is designed to provide you with important information needed to setup operate maintain and troubleshoot your cooler Failure to follow...

Page 2: ...E SECTION PAGE INTRODUCTION 3 TECHNICAL SPECIFICATIONS 3 WARNINGS AND SAFETY RULES 4 PARTS DESCRIPTION 5 ASSEMBLY INSTRUCTIONS 7 USE OPERATION Connect Water Supply 7 Start up Check List 8 Control Pane...

Page 3: ...cooled by evaporation and then discharged from the cooler The SO 3500 JC is ideal for using in patio and other outdoor application The appliance can be used as an evaporative cooler air cleaner and hu...

Page 4: ...or mechanical functions of the cooler as this may void the warranty Please check that the voltage in the area to be cooled is correct for the air cooler specification Incorrect voltage will burn out t...

Page 5: ...ont 1 Top Panel 2 Air Outlet 3 Remote Control Place 4 Control Panel 5 Cord Wrap 6 Power Cord 7 Water Tank 8 Castors Back 1 Air Filter Dust Filter Honeycomb Filter 2 Water Fill Door 3 Connection to Gar...

Page 6: ...4 Overflow Standpipe Accessories 1 Remote Control and its Bracket NOTE 2 x AAA batteries are required for remote control but are not included 2 Hardware Parts for Garden Hose Connection NOTE Garden ho...

Page 7: ...and close the water fill door 2 Connect the garden hose to garden hose connection part for water in let Fill water tank as follows 1 Turn water supply on Check for good pressure and flow from float va...

Page 8: ...eed The indicator light will show the selected speed Cool To begin cooling the desired area press the Cool button until the indicator light is on The water pump will begin to wet the pad You should be...

Page 9: ...9 Remote Control Power ON OFF Speed LOW MEDIUM HIGH Cool Control cooling or fan option Swing Control the motion of the vertical louvers Timer Control timer function for automatic shut off...

Page 10: ...bottom of the unit Once the water tank is empty replace the drain plug refill the unit and drain it again Repeat this cleaning weekly to reduce water mineral build up Replace the drain plug refill wit...

Page 11: ...ng the paper elements Step 3 Dust filter screens can be cleaned once a week Step 4 Cleaning method 1 Use a damp cloth or soft sponge with mild soap detergent to wipe the unit clean 2 Wash off dirt on...

Page 12: ...ed at the factory For your future reference the wiring diagram in Figure shows rocker switches two speed motor capacitor and pump Switches POWER SPEED COOL SWING and TIMER are located on the electroni...

Page 13: ...nment 3 Panel goes wrong 1 Power off 2 Remove or keep far away from the interference 3 Change the panel 4 Call customer service 3 Display normal but without wind or the wind speed is too low 1 The fan...

Reviews: