Upper limit value setting: in the state of returning 

to  zero,

 

press the      key more than 3s, enter the 

lower limit value setting

display "UP" and "0.0" back 

and forth, press    

 

and

      

to enter the lower 

limit value you want to set, press the     key to 
determine.

 

   Quickly set limits

Put items on scale and 

long press     

or     

  more than 3s,

         

It sets the upper and lower limits for the 

number you weigh. 

   

1>If the lower limit is 0 and the upper limit is not 

0, it represents: when the weighing data is greater than 
the upper limit value, an alarm is issued.

 

   

2>If only the lower limit value is not 0, the upper 

limit value is 0, which means: When the weighing 
data is less than the lower limit value, it will alarm.

 

   

3>If only the lower limit value is not 0, the upper 

limit value is not 0, and the lower limit value is less 
than the upper limit value, which means: when the 

weighing data is less than the lower limit value, or 
greater than the upper limit value, the alarm is issued.

 

   

4>If only the lower limit value is not 0, the upper 

limit value is not 0, and the lower limit value is greater 
than the upper limit value, which means: when the 
weighing data is greater than the lower limit value, or 
less than the upper limit value, the alarm is issued.

 

4. Counting operation

 

 

If you need do testing for the members of sample

when it 

shows zero

press      more than 3s, it 

shows PC 20, means sample have 20 pcs

 press  

  to choose sample quantity, 

20

40

60

80

100

Put same members of goods on the scale

press 

 

confirm. Press     

  again to back to counting state

.  

5

Tare 

   

If  packaging is required to weigh the item, follow these 

steps: pack  the object placed on the scale, press      to 

deduct the weight of the package. The weight value is displayed 

as zero

The display shows

“      ”

then put the goods on 

 

Summary of Contents for BN-V8U Series

Page 1: ...n manual Xiamen Uniweight Precision Co Ltd Xiamen Uniweight Precision Co Ltd No 1678 Jixian Road Tongan District Xiamen City Fujian Province China Fujian Manufacturing No 00000276 Website www uniweigh...

Page 2: ...e 4 Do not hit or press do not exceed its maximum weight capacity 5 Remove the battery when it is not in use for a long time 6 When it is found that it can t be used for a long time after charging for...

Page 3: ...weight that s the weight of the package zero the weight when emptying the scale Internal correction set the upper limit Unit change down limit setting IV Indicator symbol battery low voltage state War...

Page 4: ...on and wait for the data to stabilize press once shows Add xx After 2s the scale returns back to weight if continue to cumulative then must remove the object waiting for weight put the object on agai...

Page 5: ...er limit value is less than the upper limit value which means when the weighing data is less than the lower limit value or greater than the upper limit value the alarm is issued 4 If only the lower li...

Page 6: ...x Press the key or key to switch back and forth as follows P01 xx is back light or lighter setting 00 Represents automatic backlight or automatically adjusts brightness 01 Represents the backlight alw...

Page 7: ...itch off 01 serial communication switch on P08 xx baud rate setting 00 the baud rate is 1200 01 the baud rate is 2400 02 the baud rate is 4800 03 the baud rate is 9600 04 the baud rate is 19200 P09 xx...

Page 8: ...inner code P15 XX automatic average function setting 00 automatic average closing 01 automatic average opening P16 XX weight memory function setting 00 Weight memory function shut down 01 Weight memor...

Page 9: ...press the key to switch the correction mode 1 represents one point correction 3 represents three points correction Press key to switch the next Display SP X Press key to switch the unit 0 represents t...

Page 10: ...a point correction you can press and keys to set the value to be corrected After changing the value put it on the corresponding to the value of the weight wait for the steady light to be on press it i...

Page 11: ...Then jump to the full range value put the weight of the corresponding value wait for the steady light to light up press then the electronic scale will automatically correct this value...

Reviews: