Page 1: ...n manual Xiamen Uniweight Precision Co Ltd Xiamen Uniweight Precision Co Ltd No 1678 Jixian Road Tongan District Xiamen City Fujian Province China Fujian Manufacturing No 00000276 Website www uniweigh...

Page 2: ...e 4 Do not hit or press do not exceed its maximum weight capacity 5 Remove the battery when it is not in use for a long time 6 When it is found that it can t be used for a long time after charging for...

Page 3: ...weight that s the weight of the package zero the weight when emptying the scale Internal correction set the upper limit Unit change down limit setting IV Indicator symbol battery low voltage state War...

Page 4: ...on and wait for the data to stabilize press once shows Add xx After 2s the scale returns back to weight if continue to cumulative then must remove the object waiting for weight put the object on agai...

Page 5: ...er limit value is less than the upper limit value which means when the weighing data is less than the lower limit value or greater than the upper limit value the alarm is issued 4 If only the lower li...

Page 6: ...x Press the key or key to switch back and forth as follows P01 xx is back light or lighter setting 00 Represents automatic backlight or automatically adjusts brightness 01 Represents the backlight alw...

Page 7: ...itch off 01 serial communication switch on P08 xx baud rate setting 00 the baud rate is 1200 01 the baud rate is 2400 02 the baud rate is 4800 03 the baud rate is 9600 04 the baud rate is 19200 P09 xx...

Page 8: ...inner code P15 XX automatic average function setting 00 automatic average closing 01 automatic average opening P16 XX weight memory function setting 00 Weight memory function shut down 01 Weight memor...

Page 9: ...press the key to switch the correction mode 1 represents one point correction 3 represents three points correction Press key to switch the next Display SP X Press key to switch the unit 0 represents t...

Page 10: ...a point correction you can press and keys to set the value to be corrected After changing the value put it on the corresponding to the value of the weight wait for the steady light to be on press it i...

Page 11: ...Then jump to the full range value put the weight of the corresponding value wait for the steady light to light up press then the electronic scale will automatically correct this value...