S-CAPEPLUS Wall Cover Installation Manuallines Download Page 2

Pre-Installation

1. Assess and determine the best place to install the S-CAPEPLUS Evacuation Mattress. 
Check and make sure that the desired installation spot is suitable. Ensure that you don't drill
through water pipes or wires. 

 

2. The distance between the installation holes on the backside of the Wall Cover is 5400 mm
(horizontal) and 7650 mm (vertical). Always double check the distances using a tape measure.
 
3. Mark out the place where the wall plugs need to go. Use a straight edge. It is recommended
to install the Wall Cover 30cm-90 cm from the floor. Ensure that the operator doesn't need to
lift the Evacuation Mattress from a height that is too high.
 
4. Drill the holes on the marked positions. Place the wall plugs in the holes (picture 1). 
 
5. Place one metal ring on the outside of each installation hole and one metal ring on the inside
of each installation hole (picture 2).
 
6. Now use the screw to go through the metal rings and the installation hole. 
Insert the 4 screws in the 4 plugs and tighten.
 
7. The Wall Cover is now fixated to the wall. You can place the S-CAPEPLUS Evacuation Mat
inside the Wall Cover. 

Reviews: