4
WARNING
Keep bystanders clear from blowing debris.
WARNING
Wear a dust mask if blowing creates dust
that might be inhaled.
■
Make sure that the appliance is not plugged into
the power mains.
■
Remove the suction hose from the tank.
■
Loosen the latches and separate the upper
section from the tank.
■
Remove all the dirt and residue from the tank
and the hose.
■
Clean the foam filter by washing it with a mild
detergent.
■
Check the hoses and connections and check the
power cord for any damage.
■
When the foam filter is removed, check the float.
To do this, take the upper section by the handle
and tip it carefully so that the filter basket is
facing upwards. The float should move freely up
and down.
(Fig. 20)
■
Verify that the power cord is disconnected from
the outlet.
■
Remove noise diffuser from the blower port.
(Fig. 15)
■
While squeezing the locking lever, lift the
detachable blower from the vacuum lid.
(Fig. 16-17)
■
Insert the adaptor into the blowing port and fit on
the desired extension wands and or nozzles.
(Fig. 18-19)
■
Ensure the power switch is turned off and plug
into the power supply.
■
Firmly hold the blower before turning it on. Turn
the motor on by flipping the switch to the ‘I’ ON
position.
MAINTENANCE
OPERATION
BLOWING
This Wet/Dry Vac converts to a detachable blower
that can be used for leaf blowing in yards, decks
and patios. To use the detachable blower feature
please act per following instructions.