MAINTENANCE

WARNING:

When  servicing,  use  only  identical  Ryobi  replacement 

parts.  Use  of  any  other  parts  may  create  a  hazard  or 

cause product damage.

WARNING:

Always wear safety goggles or safety glasses with side 

shields  during  power  tool  operation  or  when  blowing 

dust. If operation is dusty, also wear a dust mask.

GENERAL MAINTENANCE

Avoid  using  solvents  when  cleaning  plastic  parts.  Most 

plastics are susceptible to damage from various types of 

commercial solvents and may be damaged by their use. Use 

clean cloths to remove dirt, dust, oil, grease, etc.

WARNING:

Do not at any time let brake fluids, gasoline, petroleum-

based products, penetrating oils, etc., come in contact 

with  plastic  parts.  Chemicals  can  damage,  weaken  or 

destroy  plastic  which  may  result  in  serious  personal 

injury.

Electric tools used on fiberglass material, wallboard, spackling 
compounds, or plaster are subject to accelerated wear and 
possible premature failure because the fiberglass chips and 
grindings are highly abrasive to bearings, brushes, commu-
tators, etc. Consequently, we do not recommended using this 
tool for extended work on these types of materials. However, 
if you do work with any of these materials, it is extremely 
important to clean the tool using compressed air.

LUBRICATION

All of the bearings in this tool are lubricated with a sufficient 
amount of high grade lubricant for the life of the unit under 
normal operating conditions. Therefore, no further lubrica-
tion is required.

BRUSH REPLA

CEMENT

See Figure 42.

The saw has externally accessible brush assemblies that 

should be periodically checked for wear.

Proceed as follows when re

placement is required:

  Unplug the saw.

WARNING: 

Failure to unplug the saw could result in accidental start-
ing causing serious injury.

  Remove brush cap with a screwdriver. Brush assembly is 

spring loaded and will pop out when you remove brush 
cap.

  Remove brush assembly.

  Check for wear. Replace both brushes when either has 

less  than  1/4  in.  length  of  carbon  remaining. 

Do  not  

replace one side without replacing the other.

  Reassemble  using  new  brush  assemblies.  Make  sure 

curvature of brush matches curvature of motor and that 
brush moves freely in brush tube.

  Make sure brush cap is oriented correctly (straight) and 

replace.

  Tighten brush cap securely. 

Do not

 overtighten.

BRUSH 

CAP

Fig. 42

BRUSH 

CAP

BRUSH 

ASSEMBLY

BRUSH 

ASSEMBLY

ADJUSTMENTS

POSITIVE STOP ADJUSTMENTS

See Figure 41.

NOTE:

 These adjustments were made at the factory and 

normally do not require readjustment.
To adjust:

  Unplug the saw.

  Using  two  wrenches  (one  on  the  lock  nut  and  one  for 

the positive stop adjustment screw), loosen the lock nut 

securing the positive stop adjustment screw.

  Loosen  the  bevel  lock  knob  by  turning  the  knob 

counterclockwise.

  Square the blade to the miter table as described in the 

Assembly 

section of this manual.

  Retighten  bevel  lock  knob.  Next,  retighten  lock  nut  

securing  the  positive  stop  adjustment  screw.  Recheck 

blade-to-table alignment.

 

NOTE: 

The above procedure can be used to check blade 

squareness of the saw blade to the miter table at both 0

°

 

and 45

°

 angles.

The saw has two scale indicators, one on the bevel scale 

and one on the miter scale. After squaring adjustments have 

been  made,  it  may  be  necessary  to  loosen  the  indicator 

screws and reset them to zero.

Summary of Contents for TS1354DXL

Page 1: ...ase of operation and operator safety When properly cared for it will give you years of rugged trouble free performance WARNING To reduce the risk of injury the user must read and understand the operat...

Page 2: ...tteries are warranted for two years HOW TO GET SERVICE Just return the power tool properly packaged and postage prepaid to an Authorized Service Center You can obtain the location of the Service Cente...

Page 3: ...overing to contain long hair ALWAYS WEAR SAFETY GLASSES WITH SIDE SHIELDS Everyday eyeglasses have only impact resistant lenses they are NOT safety glasses SECURE WORK Use clamps or a vise to hold wor...

Page 4: ...he blade touching the workpiece Allow motor to come up to full speed before starting cut MAKE SURE THE MITER TABLE AND SAW ARM BEVEL FUNCTION ARE LOCKED IN POSITION BE FORE OPERATING YOUR SAW Lock the...

Page 5: ...d before resuming operation ALWAYS STAY ALERT Do not allow familiarity gained from frequent use of the saw to cause a careless mistake ALWAYS REMEMBER that a careless frac tion of a second is sufficie...

Page 6: ...peed orbits etc per minute Do not expose to rain or use in damp locations To reduce the risk of injury user must read and understand operator s manual before using this product Eye Protection Precauti...

Page 7: ...e product to the nearest AUTHORIZED SERVICE CENTER for repair When servic ing use only identical replacement parts WARNING To avoid serious personal injury do not attempt to use this product until you...

Page 8: ...efore each use If damaged replace immediately Never use tool with a damaged cord since touching the damaged area could cause electrical shock resulting in serious injury ELECTRICAL DOUBLE INSULATION D...

Page 9: ...dropped into the blade or being placed inadvertently in contact with the blade Workpiece or Material The item on which the operation is being done Worktable Surface where the workpiece rests while pe...

Page 10: ...lumber sizes 2 x 4 Cutting Capacity with Miter at 0 Bevel 45 Maximum nominal lumber sizes 2 x 6 Cutting Capacity with Miter at 45 Bevel 45 Maximum nominal lumber sizes 2 x 4 LOWER BLADE GUARD DUST GUI...

Page 11: ...w s base CARRYING HANDLE See Figure 2 For convenience when carrying or transporting the miter saw from one place to another a carrying handle has been provided on top of the saw arm To transport turn...

Page 12: ...ng simple and easy SLIDING MITER FENCE The miter fence on the compound miter saw has been provided to hold your workpiece securely against when making all cuts The left side is larger providing additi...

Page 13: ...our Compound Miter Saw Miter Lock Handle Dust Bag Dust Guide Stop Block Small Wing Screw Clamp Brackets 2 Clamp Bracket Screws 2 Table Extensions 2 Work Clamp Blade Wrench Hex Key 5 mm Blade Washer He...

Page 14: ...RACE HOLES AT THESE LOCATIONS FOR HOLE PATTERN UNPACKING This product requires assembly Carefully lift saw from the carton by the carrying handle and the saw base and place it on a level work surface...

Page 15: ...vents the workpiece from creeping toward the saw blade This is very helpful when cutting compound miters Depending on the cutting operation and the size of the workpiece it may be necessary to use a C...

Page 16: ...screw threads through the clamp bracket and tightens against bracket support on bottom of miter table securing clamp bracket against table extension STOP BLOCK See Figures 12 and 15 The stop block is...

Page 17: ...r laser guide and outer blade washer where they contact the blade WARNING If inner blade washer has been removed replace it before placing blade on spindle Failure to do so could cause an accident sin...

Page 18: ...olored line on the work surface when the blade is spinning The red laser line will appear as a broken line on the workpiece when the blade as sembly is in the uppermost position and the motor switch i...

Page 19: ...lock plate and securely tighten the miter lock handle Lay a framing square flat on the miter table Place one leg of the square against the fence Place the other leg of the square beside the throat pl...

Page 20: ...or back edge of the saw blade angles away from the square as shown in figures 25 26 adjustments are needed Loosen the socket head screws that secure the miter fence to the miter table Rotate the mite...

Page 21: ...s are needed Loosen the lock nut securing positive stop adjustment screw Also loosen bevel lock knob See figure 41 Adjust positive stop adjustment screw to bring saw blade into alignment with the squa...

Page 22: ...ure to do so could result in movement of the control arm or miter table while making a cut WARNING To avoid serious personal injury keep hands outside the no hands zone at least 3 in from the blade Ne...

Page 23: ...electric brake stops blade from turning before removing the workpiece from the miter table TO BEVEL CUT See Figures 32 33 Abevelcutismadebycuttingacrossthegrainoftheworkpiece with the blade angled to...

Page 24: ...the bevel setting Also each time you adjust the bevel setting you change the effect of the miter setting It may take several settings to obtain the desired cut The firstanglesettingshouldbecheckedaft...

Page 25: ...erform a dry run of the cutting operation just to make sure that no problems will occur when the cut is made Grasp the saw handle firmly then squeeze the switch trigger Allow several seconds for the b...

Page 26: ...59 M 34 32 B 11 60 M 28 48 B 9 85 M 24 35 B 8 53 M 21 27 B 7 52 M 18 88 B 6 72 M 16 98 B 6 07 M 33 36 B 14 38 M 27 62 B 12 20 M 23 56 B 10 57 M 20 58 B 9 31 M 18 26 B 8 31 M 16 41 B 7 50 M 32 18 B 17...

Page 27: ...the miter saw CEILING W A L L INSIDE CORNER CROWN MOLDING FLAT ON MITER TABLE 38 52 FENCE MITER TABLE BOTTOM EDGE AGAINST FENCE RIGHT SIDE INSIDE CORNER LEFT SIDE OUTSIDE CORNER FENCE MITER TABLE Fig...

Page 28: ...edge of molding against fence 2 Miter table set left 31 62 3 Save left end of cut Left side outside corner 1 Bottom edge of molding against fence 2 Miter table set left 31 62 3 Save right end of cut...

Page 29: ...CENTER DEPTH STOP The depth stop limits the blade s downward travel It allows the blade to go below the miter table enough to maintain full cutting capacities The depth stop positions the blade 1 4 i...

Page 30: ...semblies that should be periodically checked for wear Proceed as follows when replacement is required Unplug the saw WARNING Failure to unplug the saw could result in accidental start ing causing seri...

Page 31: ...ust and debris Do not attempt to activate the laser The laser is activated by means of a centrifugal switch only while the saw motor is running and the laser guide is mounted on the saw After cleaning...

Page 32: ...repair parts always give the following information MODEL NUMBER SERIAL NUMBER ONE WORLD TECHNOLOGIES INC 1428 Pearman Dairy Road Anderson SC 29625 Phone 1 800 525 2579 www ryobitools com Ryobi is a r...

Reviews: