ELECTRICAL

DOUBLE INSULATION

Double insulation is a concept in safety in electric power
tools, which eliminates the need for the usual three-wire
grounded power cord. All exposed metal parts are isolated
from the internal metal motor components with protecting
insulation. Double insulated tools do not need to be grounded.

WARNING:

The double insulated system is intended to protect the
user from shock resulting from a break in the tool's
internal insulation. Observe all normal safety precau-
tions to avoid electrical shock.

Important:

 Servicing of a tool with double insulation requires

extreme care and knowledge of the system and should be
performed only by a qualified service technician. For service,
we suggest you return the tool to your nearest authorized
service center for repair. Always use only original factory
replacement parts when servicing.

ELECTRICAL CONNECTION

This tool has a precision-built electric motor. 

It should be

connected to a power supply that is 120 volts, 60 Hz, AC
only (normal household current).

 Do not operate this tool

on direct current (DC). A substantial voltage drop will cause
a loss of power and the motor will overheat. If your tool does
not operate when plugged into an outlet, double-check the
power supply.

IMPORTANT

Servicing of a tool with double insulation requires extreme
care and knowledge of the system and should be performed
only by a qualified service technician. For service we suggest
you return the tool to your nearest 

RYOBI

 

AUTHORIZED

SERVICE CENTER

  for repair. When servicing use only

identical Ryobi replacement parts.

EXTENSION CORDS

When using a power tool at a considerable distance from a
power source, be sure to use an extension cord that has the
capacity to handle the current the tool will draw. An undersized
cord will cause a drop in line voltage, resulting in overheating
and loss of power. Use the chart to determine the minimum
wire size required in an extension cord. Only round jacketed
cords listed by Underwriter’s Laboratories (UL) should be
used.

When working outdoors with a tool, use an extension cord
that is designed for outside use. This type of cord is designated
with "WA" on the cord's jacket.

Before using any extension cord, inspect it for loose or
exposed wires and cut or worn insulation.

**Ampere rating
  (on tool faceplate) 0-2.0 2.1-3.4

3.5-5.0

5.1-7.0 7.1-12.0 12.1-16.0

Cord Length

Wire Size (A.W.G.)

25'

16

16

16

16

14

14

50'

16

16

16

14

14

12

100'

16

16

14

12

10

**Used on 12 gage - 20 amp circuit.

WARNING:

Keep the extension cord clear of the working area. Posi-
tion the cord so that it will not become entangled in the
rotating foam pad or caught on lumber, tools or other
obstructions while you are working with the tool. Failure
to do so can result in serious personal injury.

WARNING:

Check extension cords before each use. If damaged re-
place immediately. Never use tool with a damaged cord
since touching the damaged area could cause electrical
shock resulting in serious injury.

Summary of Contents for RS2418

Page 1: ...andard for dependability ease of operation and operator safety Properly cared for it will give you years of rugged trouble free performance WARNING To reduce the risk of injury the user must read and...

Page 2: ...ndard safety glasses with side shields Always wear eye protection which is marked to comply with ANSI Z87 1 WARNING Look for this symbol to point out important safety precautions It means attention Yo...

Page 3: ...th your finger on the switch or plugging in tools that have the switch on invites accidents Remove adjusting keys or wrenches before turning the tool on A wrench or a key that is left attached to a ro...

Page 4: ...educe the risk of electric shock or fire Make sure your extension cord is in good condition When using an extension cord be sure to use one heavy enough to carry the current your product will draw A w...

Page 5: ...lds and a full face shield when operating this product Wet Conditions Alert Do not expose to rain or use in damp locations The purpose of safety symbols is to attract your attention to possible danger...

Page 6: ...ed onlybyaqualifiedservicetechnician Forservicewesuggest you return the tool to your nearest RYOBI AUTHORIZED SERVICE CENTER for repair When servicing use only identical Ryobi replacement parts EXTENS...

Page 7: ...pressure sensitive sanding discs for use with velcro type sanding discs RANDOM ORBIT The random orbit motion provides overlapping sanding movements by combining orbital and turning motion These overla...

Page 8: ...erious personal injury Fig 2 ADHESIVE SANDING DISC BACKING PAD TO ATTACH PRESSURE SENSITIVE ADHESIVE SANDING DISC See Figure 2 Unplug your sander Carefully peel paper backing from the pressure sensiti...

Page 9: ...the sanding disc backing and the conversion pad clean to provide the best attachment Clean occasionally by brushing lightly with a small brush DUSTLESS SANDING See Figures 3 and 4 The dust bag assemb...

Page 10: ...sonal injury CAUTION To ensure proper brake operation after extended use periodically check its operation by removing the sanding disc and running your sander without load off the workpiece The backin...

Page 11: ...DO NOT FORCE The weight of the unit supplies adequate pressure so let the sanding disc and sander do the work Applying additional pressure only slows the motor rapidly wears sanding disc and greatly r...

Page 12: ...remove dirt carbon dust etc WARNING Do not at any time let brake fluids gasoline petroleum based products penetrating oils etc come in contact with plastic parts They contain chemicals that can damage...

Page 13: ...0060 60 Grit Sanding Disc 5 Per Pack 4600080 80 Grit Sanding Disc 5 Per Pack 4600100 100 Grit Sanding Disc 5 Per Pack 4600150 150 Grit Sanding Disc 5 Per Pack 4600220 220 Grit Sanding Disc 5 Per Pack...

Page 14: ...79 for your nearest Ryobi Authorized Service Center You can also check our web site at www ryobitools com for a complete list of Authorized Service Centers MODEL NO AND SERIAL NO The model number and...

Reviews: