background image

Safety

2

 WARNING

To reduce the risk of electrocution, keep all connections 
dry and off the ground. Do not touch plug with wet hands.

Ŷ

To reduce the risk of injury, the product shall not be 
used by children or untrained personnel. Keep children 
and visitors away. All visitors should wear safety 
glasses and be kept a safe distance from work area.

Ŷ

Use correct product. Don’t force product or attachment 
to do a job it was not designed for. Don’t use it for a 
purpose not intended.

Ŷ

Use only recommended accessories. The use of 
improper accessories may cause risk of injury.

Ŷ

Never leave product running unattended. Turn power 
off. Don’t leave product until it comes to a complete 
stop.

Ŷ

Keep the motor free of grass, leaves, or grease to 
reduce the chance of a fire hazard.

Ŷ

Keep product dry, clean, and free from oil and grease. 
Always use a clean cloth when cleaning. Never use 
brake fluids, gasoline, petroleum-based products, or 
any solvents to clean product.

Ŷ

Do not use product if switch does not turn it off. Have 
defective switches replaced by an authorized service 
centre.

Ŷ

Avoid dangerous environments. Don’t expose to rain. 
Keep work area well lit.

Ŷ

Do not abuse the cord. Never use the cord to carry the 
product or to disconnect the plug from the outlet. Keep 
cord away from heat, oil, sharp edges, or moving parts. 
Replace damaged cords immediately by an authorised 
service agent. Damaged cords increase the risk of 
electric shock.

Ŷ

Inspect extension cords periodically and replace if 
damaged. Keep handles dry, clean, and free from oil 
or grease.

Ŷ

Before starting any cleaning operation, close doors and 
windows. Clear the area to be cleaned of debris, toys, 
outdoor furniture, or other objects that could create a 
hazard.

Ŷ

Do not use acids, alkaline, solvents, flammable 
material, bleaches, or industrial grade solutions in this 
product. These products can cause physical injuries to 
the operator and irreversible damage to the product.

Ŷ

Keep the motor away from flammables and other 
hazardous materials.

Ŷ

Check bolts and nuts for looseness before each use. 
A loose bolt or nut may cause serious motor problems.

Ŷ

Before storing, allow the motor to cool.

Ŷ

When servicing use only identical replacement parts. 
Use of any other parts may create a hazard or cause 
product damage.

Ŷ

Only use cold water.

Ŷ

Make sure minimum clearance of 1 metre is maintained 

from combustible materials.

Ŷ

Connect the product only to an individual branch circuit.

Ŷ

Hold the gun and lance securely with both hands. 
Expect the gun to move when the trigger is pulled due 
to reaction forces. Failure to do so could cause loss of 
control and injury to yourself and others.

Ŷ

Water that has flown through backflow preventers is 
considered to be non-potable.

Ŷ

Save these instructions. Refer to them frequently and 
use them to instruct other users.

Ŷ

Always operate the product on a level surface.

Ŷ

Clean the water inlet filter regularly once a month or 
more frequently according to use. Carefully loosen the 
filter with a screwdriver and clean it. Check that it is 
intact before re-mounting it.

Ŷ

The inlet filter must always be fitted inside the water inlet 
pipe to filter out sand, limestone and other impurities, as 
they will damage the pump valves.

Ŷ

Check and Clean the nozzle with the tool provided each 
start.

INTENDED USE

Ŷ

The product is intended only for the cleaning of vehicles, 
boats, buildings, etc, by the removal of stubborn dirt 
using clean water and chemical detergents. 

Ŷ

For domestic use only, not for professional use, and 
only for operation at temperatures above 0°C.

OVERLOAD PROTECTION

The product has an overload protection device that is 
activated when overheating or a current spike occurs, 
automatically shutting down power within the product. To 
resume operation, disconnect the product from the power 
supply, wait for about 15 minutes, and re-connect the 
product to the power supply.

 WARNING

+LJKSUHVVXUHKRVHV¿WWLQJVDQGFRXSOLQJVDUHLPSRUWDQW
IRUWKHVDIHW\RIWKHSURGXFW8VHRQO\KRVHV¿WWLQJVDQG

couplings recommended by the manufacturer.

 CAUTION

This product must not be used on the drinking water 

VXSSO\ ZLWKRXW D EDFNÀRZ SUHYHQWHU EHLQJ LQVWDOOHG

which corresponds to EN 12729 Type BA. Water 

ÀRZLQJWKURXJKDEDFNÀRZSUHYHQWHULVFRQVLGHUHGQRQ

drinkable. Always observe the regulations of your local 
water utility company when connecting the product to a 
water supply line.

Summary of Contents for RPW130

Page 1: ...ORIGINAL INSTRUCTIONS High Pressure Washer RPW130SC...

Page 2: ...Important It is essential that you read the instructions in this manual before operating this machine Subject to technical modifications...

Page 3: ...tection Don t overreach or stand on unstable support Keep proper footing and balance at all times WARNING High pressure jets can be dangerous if subject to misuse The jet must not be directed at perso...

Page 4: ...serious motor problems Before storing allow the motor to cool When servicing use only identical replacement parts Use of any other parts may create a hazard or cause product damage Only use cold wate...

Page 5: ...g Appliance not suitable for connection to the drinking water mains without EDFN RZ SUHYHQWHU Never point the gun to human animals the machine body power supply or any electric appliances Regulatory C...

Page 6: ...4 Unpacking x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 1...

Page 7: ...Getting Started 1 1 2 6 2 1 2 7...

Page 8: ...Getting Started 1 2 3 8 4 9...

Page 9: ...Getting Started 5 5 10 11...

Page 10: ...6 Overview p 7 p 8 p 9 p 10 p 11...

Page 11: ...7 Operation 2 1 1 2 3 2 1 1 3 2 4...

Page 12: ...8 Operation 1 2 2 1 1 2...

Page 13: ...9 Operation 1 2 1 2...

Page 14: ...10 Maintenance...

Page 15: ...11 Maintenance 1 3 4 2...

Page 16: ...12 Maintenance 1 2 1 2 6 8 7 1 2 5...

Page 17: ...13 Maintenance 9 20121119v1...

Page 18: ...PRGHO tag Thermal sensor activated Leave the washer for 15 minutes to cool down Nozzle partially blocked Clean the nozzle Fuse blows Fuse too small Change to an installation higher than the amp Consu...

Page 19: ...ressure 13 Mpa Rated pressure 9 Mpa Degree of protection IPX5 5DWHG RZ 6 L min 0D RZ 7 L min Max inlet water pressure 0 7 Mpa Sound pressure level Uncertainty LpA 77 dB A KpA 3 dB Sound power level Un...

Page 20: ...Techtronic Product Development Limited 24 F CDW Building 388 Castle Peak Road Tsuen Wan Hong kong Techtronic Industries Australia New Zealand Doncaster Victoria Mt Wellington Aukland...