Ryobi RGN1200A Operator'S Manual Download Page 6

5

English

other than the equipment grounding conductor. 

Failure to isolate the generator from power utility 

can result in death or injury to electric utility 

workers. 

n

 

Exhaust fumes contains poisonous carbon 

monoxide, a colourless, odourless gas. Breathing 

exhaust fumes can cause loss of consciousness and 

can lead to death. If running in a confined or partially-

enclosed area, the air may contain a dangerous 

amount of carbon monoxide. To keep exhaust 

fumes from building up, always provide adequate 

ventilation.

n

 

Always use a battery-powered carbon monoxide 

detector when running the generator. If you begin to 

feel sick, dizzy, or weak while using the generator, 

shut it off and get to fresh air immediately. See a 

doctor. You may have carbon monoxide poisoning.

n

 

Place the generator on a flat, stable surface with a 

slope of no more than 4°.

n

 

Operate in a well-ventilated, well-lit area isolated 

from working areas to avoid noise interference.

n

 

Operating the generator in wet conditions could 

result in electrocution. Keep the unit dry.

n

 

Keep the generator a minimum of 1m away from all 

types of combustible material. 

n

 

Do not operate the generator near hazardous 

material.

n

 

Do not operate the generator at a petrol station.

n

 

Do not touch the muffler or cylinder during or 

immediately after use; they are HOT and will cause 

burn injury.

n

 

Do not connect to a building’s electrical system 

unless a transfer switch has been properly installed 

by a qualified electrician.

n

 

Do not allow the generator’s fuel tank to overflow 

when filling. Fill to 25mm below the top neck of the 

unleaded fuel tank to allow for fuel expansion. Check 

the ventilation hole inside the fuel tank cap for debris. 

Do not block the vent.

n

 

Do not smoke when filling the generator with 

unleaded fuel.

n

 

Allow the engine to remain in a shut-down condition 

for at least five minutes before adding unleaded fuel 

or oil.

n

 

Do not remove the oil dipstick or the fuel tank cap 

when the engine is running.

n

 

Pay close attention to all safety labels located on the 

generator.

n

 

Keep children a minimum of 3m away from the 

generator at all times.

n

 

The unit operates best in temperatures between 5°C 

and 40°C with a relative humidity of 30~95%.

n

 

Operation of the generator at altitudes above 1,000m 

may require retuning. Consult a qualified service 

technician.

n

  When using extension lines or mobile distribution 

networks the total length of lines for a cross section 

of 1.5mm

2

 should not exceed 60m; for a cross 

section of  2.5mm

2

 this should not exceed 100m.  

n

  The generating set must not be connected to other 

power sources

n

 

Save these instructions. Refer to them frequently and 

use them to instruct others who may use this tool. If you 

loan someone this tool, loan them these instructions 

also.

Summary of Contents for RGN1200A

Page 1: ...E GENERATOR SET OPERATOR S MANUAL RGN1200A Important It is essential that you read the instructions in this manual before assembling maintaining and operating this machine Subject to technical modific...

Page 2: ...Fig 4 Fig 5 Fig 3 OIL CAP DIPSTICK RECOIL STARTER GRIP AIR FILTER CHOKE LEVER FUEL CAP CIRCUIT BREAKER FUEL TANK FUEL CAP OIL CAP DIPSTICK OIL FILL HOLE CARBURETOR DRAIN SCREW OIL CAP DIPSTICK Fig 2 F...

Page 3: ...2 Fig 6 ON OFF ON OFF Fig 8 Fig 7 AIR FILTER RECOIL STARTER GRIP FUEL VALVE Fig 9 CHOKE LEVER TO START CHOKE CLOSED TO RUN CHOKE OPEN LATCHES CHOKE LEVER TO START CHOKE CLOSED LATCHES...

Page 4: ...3 21 2 Fig 10 ON OFF Fig 11 Fig 12 Fig 13 ON OFF ON OFF SPARK PLUG CAP SPARK PLUG FUEL LINE FUEL VALVE BARB FUEL VALVE O RING FILTER SEDIMENT CUP OIL DRAINAGE PLUG...

Page 5: ...or receptacles n Do not use the generator with electrical cords which are worn frayed bare or otherwise damaged n Before storing allow the engine to cool n Do not operate the generator in rain snow or...

Page 6: ...diately after use they are HOT and will cause burn injury n Do not connect to a building s electrical system unless a transfer switch has been properly installed by a qualified electrician n Do not al...

Page 7: ...d to observe safe practices can result in electric shock Running the generator gives off carbon monoxide an odourless colourless poison gas Breathing carbon monoxide can cause nausea fainting or death...

Page 8: ...ormed only by a qualified service technician For service contact your nearest AUTHORISED SERVICE CENTRE for repair When servicing use only identical replacement parts WARNING Observe all normal safety...

Page 9: ...The unit is equipped with an oil sensor which will automatically shut off the engine if oil level falls below a safe limit HOT SURFACE WARNING Do not touch the muffler or aluminium cylinder of the eng...

Page 10: ...scribed later in this manual 2 Plug in and turn on the first load preferably the largest load highest wattage you have 3 Permit the generator output to stabilise engine runs smoothly and attached devi...

Page 11: ...Engine Number UP154 Engine Type 4 Stroke air cooled OHV Gasoline Bore x Stroke mm 54 x 38 Displacement cc 87 Starting System recoil Fuel Type Unleaded fuel Lubrication oil SAE 10W 30 Engine Oil Volum...

Page 12: ...orhasthefollowingsinglephase 50Hzoutlets one 230 Volt AC 15 Amp receptacle These can be used for operating appropriate appliances electrical lighting tools and motor loads RECOIL STARTER GRIP The reco...

Page 13: ...l injury APPLICATIONS This generator is designed to supply electrical power for operating compatible electrical lighting appliances tools and motor loads BEFORE OPERATING THE UNIT Position the generat...

Page 14: ...enerator n Start the engine refer to STARTING THE ENGINE section NOTE Do not start the vehicle while the battery charging cable is connected and the generator is running The vehicle or the generator m...

Page 15: ...lowing the instructions in the Checking Adding Oil section n Reinstall the oil cap dipstick NOTE Used oil should be disposed of at an approved disposal site See your local oil retailer for more inform...

Page 16: ...fuel being drained from the tank n Open fuel valve n When the fuel has drained from the tank close the fuel valve and reinstall fuel line on barb DRAINING THE CARBURETOR See Figure 2 n Turn the engine...

Page 17: ...torage life For recommendations contact your nearest authorised service center MAINTENANCE SCHEDULE Before each use After 1st month or 20 hours of operation Every 3 months or 50 hours of operation Eve...

Page 18: ...cuit breaker is OFF Item plugged in is defective Turn ON the AC circuit breaker Try a different item Generator makes a spark knock or pinging noise An occasional light knocking or pinging underheavylo...

Page 19: ...18 English WIRING DIAGRAM RGN1200A...

Page 20: ...Techtronic Industries Australia Pty Ltd Level 1 660 Doncaster Road Doncaster VIC 3108 Australia Techtronic Industries New Zealand Ltd 18 26 Amelia Earhart Avenue Mangere Auckland 2022 New Zealand...

Reviews: