8
UNDERSTANDING THE CONTROL PANEL
1. AC socket which supplies rated output.
2. Electronic engine switch.
3. Oil pressure alarm indicator (Red).
A. lt will start flashing when the engine starts
with insufficient amount of engine oil.
B. lt illuminates red indicating oil level below
the safe limit before the engine automatically
shuts down within 10 seconds.
4. Output indicator light (green) will remain ON
during operation. However, when the green
light starts flashing:
A. lnterval Flash 1 time, low-voltage protection,
engine speed low.
B. lnterval Flash 2 times, high temperature
protection.
C. lnterval Flash 3 times, overload protection,
too many loads.
D. lnterval Flash 4 times, short-circuit
protection.
The output power will be cut off should the
generator is experiencing any of the faults that are
mentioned above. User will need to stop the engine
to fix the issue before restarting the engine.
5. Safety grounding bolt.
6. 5V USB socket.
4
1
3
2
LOCATION AND GROUNDING
Before using this generator it must be prepared
correctly before use. Locate the generator on firm
level ground away from buildings or other
structures ensuring that the exhaust is not
obstructed.
Your generator must be properly connected to an
appropriate ground to help prevent electric shock.
WARNING.
Failure to properly ground
the generator can result in electric shock.
A ground terminal connected to the frame of the
generator has been provided on the power panel.
For remote grounding, connect of a length of heavy
gauge (12 AWG minimum) copper wire between the
generator ground terminal and a copper rod driven
into the ground. We strongly recommend that you
consult with a qualified electrician to ensure
compliance with local electrical codes.
5
6