background image

1

English

GENERAL SAFETY RULES

 

Always wear personal protective safety glasses, 
gloves, ear protectors, face mask or respiratory 
equipment and protective clothing.

 

Always ensure machine is switched off before 
connecting to air supply.

 

Disconnect any machine from the air supply before 
changing blades or discs, and before servicing any 
type of machine.

 

Do not wear watches, rings bracelets or loose clothing 
when using air tools.

 

Do not overload the machine. Allow the tool to operate 
at its optimum speed for maximum efficiency.

 

Do not increase the air pressure above the 
manufacturers recommended level, as excessive 
overload can cause the machine casing to split. Also 
this creates excessive wear on moving parts and 
possible failure.

 

In the interests of safety and possible damage to the 
machine/operator, always ensure that the machine 
has stopped before putting it down after use.

 

Always ensure that the accessories such as blades, 
discs, sockets, etc. are rated/designed for use with the 
machine. Also correctly and securely fastened before 
connecting the machine to the air supply.

 

Ensure you read, understand and apply safety 
instructions before use.

 

Keep children away from the tool and workplaces 
when using the tools.

 

Air tools are not generally insulated and should not 
come in contact with electric power sources.

 

Air tools should not be used in a potentially explosive 
environment.

 

Disconnect the tool from the energy source before 
changing or adjusting the inserted tool.

 

Pay attention to the risk of hair or loose clothing being 
drawn in or trapped in the tool.

 

Pay attention to the risk of being injured if hands are 
not kept away from nut runner sockets.

 

Pay attention to high speed splinters being emitted 
from impact wrenches in case of nut runner socket 
failure.

 

Pay attention to the whipping compressed air hose.

 

Unexpected direction of inserted tool movement can 
cause a hazardous situation.

 

Use only sockets and adapters which are in good 
condition and are intended for use with air tools.

 

Make sure the assembly air tool is securely fixed on a 
suspension device, if used.

 

Unsuitable postures may not allow counteracting of 
normal or unexpected movement of the tool.

 

Unexpected tool movement due to reaction forces or 
breakage of inserted tool may cause injuries.

 

Ensure that the pressure of the air or fluid supply is 
not lower than the lowest pressure specified by the 
manufacturer for clutch-controlled assembly tools and 
make sure that the air or fluid supply pressure does 
not fall after the clutch has been set.

 

Support handle and reaction bar are not required for 
this product.

 

The spare parts would not affect the health and safety 
of the operator.

SYMBOLS

Wear ear protection

Wear eye protection

 

Please read the instructions carefully before 
starting the tool.

SPECIFICATIONS

Square drive

12.5 mm (1/2”)

Capacity Bolt Size

16 mm (5/8”)

No-load speed

7,500 rpm

Max torque

567N.m (420ft/lb)

Avg. air consumption

142.5 L/min (5 cfm)

Operating pressure

90 psi (6.3bar)

Air inlet size

6.35 mm (1/4”)

Air hose ID

9.52 mm (3/8”)

Weight

2.6 kg (5.70 lb.)

A weighted sound 
pressure level

91.6 dB + 3 dB

Sound power level

102.6 dB + 3 dB

Vibration value

4.35 m/s2

Uncertainty

0.505 m/s2

Noise Emission Values is in accordance with EN ISO 4871 
and EN ISO 15744.
Vibration emission value is in accordance with EN 12096, 
EN 28662-1 and EN ISO 8662-7.