background image

3

no batteries can come in contact with other batteries or 

conductive materials while in transport by protecting exposed 

connectors with insulating, non-conductive caps or tape. Do 

not transport batteries that are cracked or leaking. Check with 

the forwarding company for further advice.

RESIDUAL RISKS

Even when the product is used as prescribed, it is still 

impossible to completely eliminate certain residual risk 

factors. The following hazards may arise and the operator 

should pay special attention to avoid the following:

 

Use the product only for its intended use. Do not alter or 

modify the product from the original design or function.

 

Always be aware that misuse and improper handling 

of the product can cause injury to yourself and others.

BLEED VALVE

See page 8.

The presence of air inside the grease tube can cause the 

grease gun to stall or stop during operation. Use the bleed 

valve to purge this air from the system after loading grease 

or as needed during operation.

 

Remove the battery pack.

 

Loosen but do not remove the bleed valve to allow 

trapped air to escape.

 

Tighten the bleed valve.

 

Install the battery pack.

 

Grasp the high pressure hose by the spring guard and 

remove it from the hose clamps.

 

Point the grease coupler towards an approved grease 

container.

 

Press the lock-off button to the unlocked position, and 

press the switch trigger to start the flow of grease.

 

If the grease gun continues to stall and grease does not 

flow, repeat these steps.

MAINTENANCE

 

 WARNING

The product should never be connected to a power 

supply  when  assembling  parts,  making  adjustments, 

cleaning, performing maintenance, or when the product 

is not in use. Disconnecting the product from the power 

supply will prevent accidental starting that could cause 

serious injury.

 

 WARNING

When servicing, use only original manufacturer’s 

replacement parts, accessories and attachments. Use of 

any other parts may create a hazard or cause product 

damage.

 

Avoid using solvents when cleaning plastic parts. Most 

plastics are susceptible to various types of commercial 

solvents and may be damaged by their use. Use clean 

cloths to remove dirt, carbon dust, etc.

 

 WARNING

Do not at any time let brake fluids, gasoline, petroleum-

based products, penetrating oils, etc., come in contact 

with plastic parts. Chemicals can damage, weaken or 

destroy plastic which may result in serious personal 

injury.

 

 WARNING

For greater safety and reliability, all repairs should be 

performed by an authorised service centre.

CLEANING THE CHECK VALVE AREA
See page 13.

If  grease  does  not  flow  freely  when  the  switch  trigger  is 

depressed, contaminants may be clogging the check valve 

area. Refer to page 13 to clean the check valve area.

ENVIRONMENTAL PROTECTION

Recycle raw materials instead of disposing 

of as waste. The machine, accessories, and 

packaging should be sorted for environment-

friendly recycling.

SYMBOLS ON THE PRODUCT

Safety alert

No-load speed

V

Volts

Direct current

min

-1

Revolutions or reciprocations per minute

Regulatory Compliance Mark (RCM). 

Product meets applicable regulatory 

requirements.

Please read the instructions carefully 

before starting the machine.

Waste electrical products should not 

be disposed of with household waste. 

Please recycle where facilities exist. 

Check with your local authority or 

retailer for recycling advice.

SYMBOLS IN THIS MANUAL

Note

Parts or accessories sold separately

Summary of Contents for R18GG450

Page 1: ...ORIGINAL INSTRUCTIONS Grease Gun R18GG450...

Page 2: ...Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modification...

Page 3: ...cted supply Use of an RCD reduces the risk of electric shock PERSONAL SAFETY Stay alert watch what you are doing and use common sense when operating a power tool Do not use a power tool while you are...

Page 4: ...acement parts This will ensure that the safety of the power tool is maintained Never service damaged battery packs Service of battery packs should only be performed by the manufacturer or authorized s...

Page 5: ...s cleaning performing maintenance or when the product is not in use Disconnecting the product from the power supply will prevent accidental starting that could cause serious injury WARNING When servic...

Page 6: ...which if not avoided will result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potenti...

Page 7: ...1 LED light 2 Lock off button 3 Switch trigger 4 Handle insulated gripping surface 5 Battery port 6 Barrel 7 Rod handle 8 High pressure hose 9 Bleed valve 10 Bolt 11 Bulk fill port 12 Hose clamp 13 G...

Page 8: ...6 5 1 6 2...

Page 9: ...7 3 3 7 4...

Page 10: ...8 10s 3 1 2 4 3...

Page 11: ...9 1 2 4 3...

Page 12: ...10 1 2 3 4 3...

Page 13: ...11 3 7 3 6 5...

Page 14: ...12 3 1 2 3 4 3...

Page 15: ...13 3 4 5 6...

Page 16: ...14 15s 3 3 1 2 4 3 20191021v1...

Page 17: ...15 3 30s 6 5...

Page 18: ...he effects of vibration such as maintain the tool and the accessories keep the hands warm and organisation of work patterns PRODUCT SPECIFICATIONS Grease Gun Model R18GG450 Voltage 18 V Grease type Up...

Page 19: ......

Page 20: ...2019 Techtronic Cordless GP All rights reserved 961075582 01 Techtronic Industries Australia Pty Ltd 31 Gilby Road Mount Waverley VIC 3149 Australia Techtronic Industries N Z Limited Unit C 70 Busine...

Reviews: