background image

9

KNOW YOUR LOG SPLITTER

( Fig.1)

Before attempting to use this product, familiarise yourself 
with all operating features and safety rules.

BLEED SCREW

Loosen the bleed screw (1) to ensure the smooth flow of air 
in and out of the oil tank.

HYDRAULIC CONTROL LEVER 

Push down on the hydraulic control lever (2) and the ram(3) 
starts pushing the log into the wedge (17).

LIFT HANDLE

The  lift  handle  (8)  makes  rolling  the  log  splitter  from  one 
location to another simple and easy.

RESET/OVERLOAD BUTTON

If the motor is overloaded the machine will shut off. Remove 
the load and push the reset/overload button (15) to restart 
the machine.

OIL DRAIN BOLT WITH DIPSTICK

Oil drain bolt with dipstick (4) makes checking and changing 
hydraulic oil easy.

SIDE SUPPORTS

Side supports (5) on each side of the work table (16) keep 
logs resting securely on the log splitter.

WORK TABLE

Provides surface to support log prior to splitting operation.

UNPACKING

n

Carefully remove the tool and any accessories from the 

box. Make sure that all items listed in the packing list 
are included.

n

Inspect the tool carefully to make sure no breakage or 

damage occurred during shipping.

n

Do  not  discard  the  packing  material  until  you  have 

carefully inspected and satisfactorily operated the tool.

WARNING:

If any parts are missing do not operate this tool until the 
missing parts are replaced. Failure to do so could result 
in possible serious personal injury.

WARNING: 

Do not attempt to modify this tool or create accessories 
not  recommended  for  use  with  this  tool.  Any  such 
alteration  or  modification  is  misuse  and  could  result 
in  a  hazardous  condition  leading  to  possible  serious 
personal injury.

WARNING:

Do  not  connect  to  power  supply  until  assembly  is 
complete. Failure to comply could result in accidental 
starting and possible serious personal injury.

9.  Axle
10.Hitch pin
11.Washer
12.Dip stick
13.Level indicator marks
14.Wood wedge
15.Reset button
16.Work table
17.Wedge

PRODUCT SPECIFICATIONS

Maximum Hydraulic Cylinder Pressure ...................16 MPa
Force .......................................................................... 4tons
Oil Capacity ................................................................. 3.5 L
Voltage ........................................................... 230 V~50 Hz
In Put Power ............................................................1500 W
No Load Speed ..........................................2970±10% rpm
Measured sound power level ....................... L

WA

 80.8 dB(A) 

K

WA 

3.0 dB(A)

Measured sound pressure level ....................L

PA

 68.6 dB(A) 

K

PA 

3.0 dB(A)

Net Weight ..................................................................49 Kg
Log Capacity Diameter, maximum ..........................250mm
Log Capacity Diameter, minimum ...........................100mm
Log Capacity Length ...............................................520mm
Vibration ..................................................................2.5m/s

2

DESCRIPTION

1.  Bleed screw
2.  Hydraulic control lever
3.  Ram
4.  Oil drain bolt with dipstick
5.  Side supports
6.  Push button box
7.  On / Off switch
8.  Lift handle

PACKING LIST

1 x Log splitter
1 x Manual
2 x Wheel

2 x Axle
4 x Washer
2 x Hitch pin

FEATURES

ASSEMBLY

ENGLISH (Original Instructions)

Summary of Contents for ELS-52

Page 1: ...1500W ELECTRIC LOG SPLITTER OPERATOR S MANUAL Original Instructions ELS52 WARNING It is essential that you read the instructions in this manual before operating this machine...

Page 2: ......

Page 3: ...14...

Page 4: ......

Page 5: ...aycausetheriskofpersonalinjury Instructionsfor safe use of accessories are included with the accessory WARNING Read and understand all instructions Failure to follow all instructions listed below may...

Page 6: ...tion If injured by escaping fluid see a doctor at once Serious infection or reaction can develop if proper medical treatment is not adminis tered immediately n KEEP THE OPERATOR ZONE and adjacent area...

Page 7: ...n operating this product Wear Gloves Wear Safety Footwear Always wear nonslip safety footwear when operating this product Always keep bystanders at least 10 ft 3 m away Keep Bystanders Away Keep Hands...

Page 8: ...ose or exposed wires and cut or worn insulation WARNING Keep the extension cord clear of the working area Position the cord so that it will not get caught on timber tools or other obstructions while y...

Page 9: ...d satisfactorily operated the tool WARNING If any parts are missing do not operate this tool until the missing parts are replaced Failure to do so could result in possible serious personal injury WARN...

Page 10: ...until the proper level is reached n If there is the proper amount of oil in the oil tank wipe the dipstick clean then replace it in the oil tank and tighten the oil drain bolt securely NOTE See Repla...

Page 11: ...with fresh hydraulic oil 3 5L n Place the cleaned dipstick into the oil tank Remove and check the oil level NOTE The oil level should be between the two oil lines around the bottom of the dipstick as...

Page 12: ...ulic system 1 Air sealed in hydraulic system while operating 2 Bleed screw is not tightened before moving the log splitter 3 Oil drain bolt is not tight 4 Hydraulic control valve assembly and or seal...

Page 13: ...cover belts brushes bags bulbs or any part which ordinary wear and tear results in required replacement during warranty period This warranty does not cover transportation cost or consumable items suc...

Page 14: ...0 960 238 TECHTRONIC INDUSTRIES AUSTRALIA PTY LIMITED Building B Rosehill Industrial Estate 3 Shirley Street Rosehill NSW 2142 Australia Tel 02 8892 1800 or 1300 361 505 Fax 1800 807 993 TECHTRONIC IN...

Reviews: