10 — English
FILTER MAINTENANCE
See Figure 21, page 17.
Periodically check the filter at the end of the water tube for
debris and to make sure it is in good condition. Remove the
plastic filter cover and rinse or replace the filter, then snap
the cover back together.
DISCONNECTING THE WATER TUBE FROM
THE T-CONNECTOR
See Figure 22, page 17.
For maintenance, replacement, or cleaning, it may be
necessary to disconnect the water tube from the T-connector.
Remove the battery pack.
Remove the blue ring from the T-connector.
Push the collar toward the T-connector while pulling the
water tube in the opposite direction to release the tube.
To replace the tube, see
Installing the Misting Hose
Assembly into the Hood
in the
Assembly
section of this
manual.
When the water tube is secured in the T-connector, re-
place the blue ring.
MAINTENANCE
ACCESSORIES
To order these accessories, call 1-877-297-8911.
Brass Misting Nozzle (5pk) .................................................................................................................. Model No. MAC080
Nozzle Cleaner .................................................................................................................................. Model No. MACC008
WARNING:
Current attachments and accessories available for use with this product are listed above. Do not use any attachments
or accessories not recommended by the manufacturer of this product. The use of attachments or accessories not
recommended can result in serious personal injury.
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
Leak at nozzle, threaded hole, or
connection
Nozzles clogged or dirty.
Misting tube or water hose connected
improperly.
Clean nozzles.
Reconnect misting tube or water hose.
This product has a four-year Limited Warranty.
For Warranty details go to www.arcticcove.com