Thank  you  very  much  for  purchasing  RynoWorx  crack  maintenance  equipment.  We  pride  ourselves  in  being 
different from other equipment manufacturers with a relentless focus on innovation, simplicity, and quality. 

RY Series Melter / Applicators are designed to effectively melt and apply direct-fire type crack sealant to joints 
and  cracks  found  in  hard  aggregate  surfaces.  This  melter  is  powered  by  a  liquid  propane  gas  burner,  which 
effectively melts crack sealants within the kettle. 

This melter was designed to be used wi

th ‘Direct Fire’ crack sealants only. Please be sure to purchase the correct 

material to ensure safe and effective operation. 

Within this document are complete instructions for how to assemble, use and care for your equipment. 
Please make sure you read and follow all instructions provided. 

Within this document you will find the following resources: 

 

Assembly/ Setup Instructions

 

– These instructions will assist you in assembling and preparing your 

melter for first time use.  

 

Operation Guide 

– This guide will explain the controls and functions of the melter and how to use them. 

 

Maintenance Guide 

 This guide will provide you with suggested maintenance tips and techniques to 

ensure proper function and optimal performance. 

 

Troubleshooting  Guide 

– 

This  guide  will  provide  you  with  the  most  commonly  reported  problems, 

possible causes, and known solutions. 

 

 

 

Required Tools

 

Required:

 

 

2 x 13 mm Wrenches or Sockets 

 

19 mm or 3/4" Wrench or Socket 

 

17 mm Wrench 

 

22 mm Wrench 

Optional:

 

 

Needle Nose Pliers 

 

Adjustable wrenches to substitute for any wrench above 

 

 

 

What’s Included in the Box

 

The next 2 pages show which parts are included in each of the 2 boxes this machine ships in. 

 

 

 

 

 

 

Summary of Contents for RA-MLT-0015

Page 1: ...Operator s Manual Model RY10MA V3 Base Model MPN RA MLT 0015 10 Gallon Direct Fire Melter Applicator Torch Model...

Page 2: ...Facebook Messenger support rynoworx com WhatsApp Messaging 519 404 9775 Website Chat rynoworx com support Email support rynoworx com Phone 855 382 9611...

Page 3: ...d it must be properly requalified to continue using Ensure that your propane cylinder is within its expiry date for your local jurisdiction The manufacturing date is stamped on the collar of the tank...

Page 4: ...4 9 RA GCM 0015 1 MA Torch Complete Assembly 10 RA BAS 0078 1 MA10 Torch V3 Handle Bar Assembly 11 RC FAB 0171 1 MA10 Torch V3 Tank Shelf 12 RC FAB 0133 1 Tank Spacer MA V4 13 RC FAB 0101 1 Melter Lid...

Page 5: ...or Melter Applicator Rear Wheel RA WHL 0005 Front Caster with Wheel RC STK 0001 Flint Striker RC WHL 0014 4 Bolt Caster Swivel RC GCM 0016 Torch for Melter Applicator with Valve RC GCM 0067 Thermomete...

Page 6: ...our equipment Please make sure you read and follow all instructions provided Within this document you will find the following resources Assembly Setup Instructions These instructions will assist you i...

Page 7: ...MA10 Torch V3 Tank Shelf 3 RA BAS 0071 1 Valve and Shoe Sub Asy 4 RC FAB 0143 1 Agitation Sweep Bar MA V4 5 RA WHL 0026 2 Rear Wheel Assembly with Bearings Melter Applicator V2 P N Model Rev RA MLT 00...

Page 8: ...ch V3 Agitation Handle 6 RC FAB 0151 1 Lid Handle MA V4 7 RC FAB 0147 1 Thermometer Guard MA V4 8 RC GCM 0016 1 Torch for Melter Applicator with Valve 9 RC GCM 0068 1 Regulator and Hose 0 30 Psi with...

Page 9: ...Assembly Instructions 1 Tank Shelf 2 Tank Spacer RK FAS 0066 13 mm Wrench RK FAS 0067 13 mm Wrench...

Page 10: ...3 Rear Wheels 4 Caster RK FAS 0080 Assemble wheels on axle the side with the bearing retainer ring should be facing out RK FAS 0065 19 mm or Wrench Insert pin...

Page 11: ...ned so it is perpendicular to the ground before the bolts are tightened The lock washers provided for the valve are shipped in pairs Use 1 pair for each bolt with the wedged surfaces on the washers ma...

Page 12: ...6 Handle Bars Bend the handle bars over the mounting studs one side at a time RK FAS 0083 19 mm or Wrench...

Page 13: ...7 Thermometer 8 Thermometer Guard RK FAS 0071 13 mm Wrench Thread the thermometer into the kettle...

Page 14: ...9 Agitation...

Page 15: ...Remove the nuts threaded on the studs and install the agitation sweep bar as shown put it over the left stud first and then the right RK FAS 0071 13 mm Wrench...

Page 16: ...Thread the provided nuts back on the stud and tighten just past flush with the end 19 mm or Wrench 2 x RC NUT 0023...

Page 17: ...10 Lid Handle RK FAS 0070 13 mm Wrench...

Page 18: ...11 Shoe Control Arm Insert the shoe control handle into the lower guide Insert the lower end of the shoe control rod into the shoe tab and insert the retaining pin...

Page 19: ...ove the top cotter pin Insert the lower end of the control rod into the valve connector rod and insert the retaining pin Turn the valve connector rod clockwise until it is tight and then turn it appro...

Page 20: ...Set Up Adjust Spring Tension The spring tension on the valve control arm can be adjusted by setting the pin position shown below which will increase or decrease the spring tension...

Page 21: ...Set Up Installing the Torch Connect the torch to the 30 psi adjustable regulator Left hand thread 19 mm wrench Insert the torch into the mounting bracket...

Page 22: ...ne tank Place your propane tank on the shelf and secure with the ratchet strap Only tighten the ratchet strap so that it is snug do not apply excess force on the brackets Connect the regulator to the...

Page 23: ...no leaks or physical damage 4 You are outdoors in a well ventilated area that is free and clear of any flammable matter 5 You have completed the assembly of the equipment correctly 6 You have Direct...

Page 24: ...suring sealant is resting on the bottom of the kettle 5 Remove the torch from the kettle and make sure the valve on the torch handle is fully OPEN by turning it COUNTERCLOCKWISE 6 Slowly turn the regu...

Page 25: ...ill eventually plug or block your flow valve which can slow down the applications process Part 3 Dispensing Crack Filler Once you have effectively liquefied the crack sealant you may begin applying it...

Page 26: ...are recommended Description Before Each Use Every 25 Hours Every 75 Hours Check Propane Tank fuel level refill as needed X Inspect regulator and hose for physical damage or leaks X Inspect front cast...

Page 27: ...ve may not be fully open and therefore restricting fuel flow or your regulator may not be providing enough pressure 3 The wind may be blowing out the flame 1 Refill your fuel tank 2 Ensure your fuel t...