CLAMPMITTER

TM

 C

onTRoLs

 & I

ndICAToRs

•  LED color indicates selected frequency

•  Solid LED indicates normal output power

• 

Rapid flashing LED indicates high-power output

• 

Slow flashing LED indicates low battery

•  Short press turns on unit

•  Short press toggles frequencies

•  Two-second press enables high-power output

•  Four-second press turns unit off

Signal LED Indications 

Key Functions 

•  Red LED indicates charging

•  Blue LED indicates full charge

Charging LED Indications 

•  Micro-USB charging under protective plate

Charging Port 

The CLAMPMITTER

TM

 is used to induce a tracing signal on a target conductor when direct connection is 

not possible, and/or when services cannot be interrupted . 
Induction coupling may be better than direct connection at applying selective signal to a target conductor 

with less inadvertent coupling to adjacent lines . It is common for the target conductor to carry the strongest 

signal, and non-target lines will carry a weaker signal . 
Successful coupler operation requires an insulated conductor that is grounded on both near and far ends . 

It is best to leave the system grounds intact, or ground the line if possible, when coupling signal .   N

ote

:

 

An insulated conductor may be may be traced without near and far end grounds if a sufficient length of 

cable is buried underground on either side of the point of coupling . In this case the signal will capacitive 

couple to ground .  

• Turn the CLAMPMITTER

TM

 on and select the desired frequencies and output power . 

• Clamp the coupler around the cable with the coupler around the wire closer to the outgoing cable, not 

near the system ground . The result will be a stronger signal .

c

oupler

 i

nDuction

 c

onnection

1 . 8 1 6 . 3 5 3 . 2 1 0 0  

             