ryan JYCD02 Instruction Manual Download Page 9

1.

Fill solution to the tank and fasten the cap.

2.

Choose the right nozzle sizes according to your need. 
The nozzle sizes referring to the above parameters sheet. 
Fix the nozzle and turn on to spray.

Operation Instructions

1. 

Malfunction: the machine doesn't work.

Causes

A.

plug connection is loosed, bad contact;
Solution: change if it's loose

B.

switch damage
Solution: replace with a new one

C.

carbon brush wear
Solution: replace with new one. The steps are as followed:

a.

Dismantle the series motor from the tagger; do not interfere 
with other spare parts.

b.

Press the rabbet by screwdriver at the position as illustration.

c.

Pull the carbon brush out of the support by long flat nose 
piers. 

d. 

Bare the wire of series motor and compress the new carbon 
brush with power wire.

e.

Put the carbon brush to the motor support, and press the 
carbon brush to the bottom.

f.

Last step is to fix the series motor back to its original place - 
motor case.

Trouble Shooting

06

Summary of Contents for JYCD02

Page 1: ...1 833 649 2111 www ryanprecisionequipment com...

Page 2: ...fety operation instructions and use the machine properly to improve the efficiency and to extend the service life of the machine You can contact with your local distributors or directly contact us for...

Page 3: ...I Read Before Use 01 II Technical Parameters 02 III Application Fields 03 IV Features 03 V Parts List 04 VI Operation Instructions 06 VII Trouble Shooting 06 VIII Detailed List In Case 08 CONTENTS...

Page 4: ...obvious change in the voice of motor solution leakage the motor doesn t work when turned on or other dangerous situations 5 Must use proper personal protective equipment while using fogger 6 After us...

Page 5: ...t 3 4kg Measurement 670 x 220 x 280 spray time and average particle size diameter scope Nozzle Model Qualification 1 nozzle head approx 20min l 20 10 m 2 nozzle head approx 10min l 40 10 m 3 nozzle he...

Page 6: ...otel fitness centre office buildings warehouse factory etc Application Fields Ability to change different diameter of nozzle controlling fog drop particle precision to meet a variety of spray work Por...

Page 7: ...Parts List 04...

Page 8: ...2 1 09 13 sprayer head support frame JYCD02 1 10 14 sprayer head gimbal lock JYCD02 1 11 15 silica gel O ring 6 1 8 70 16 spiral sprayer head JYCD02 1 12 17 sprayer head cap JYCD02 1 13 18 atomization...

Page 9: ...h a new one C carbon brush wear Solution replace with new one The steps are as followed a Dismantle the series motor from the tagger do not interfere with other spare parts b Press the rabbet by screw...

Page 10: ...e the components to the original place B The outlet pipe has fallen off Solution disassemble the nozzle components to find their linked support extract the support and outlet pipe and then put the pip...

Page 11: ...Detailed List In Case 1 Fogger body 1 2 Carbon brush 2 Spare parts reserved 3 Belt 1 4 Operating Insruction Manual 1 5 Product Qualification Certificate 1 Item Name Qty Remark 08...

Page 12: ...RYAN PRECISION EQUIPMENT LTD 1 833 649 2111 www ryanprecisionequipment com...

Reviews: