RWD WJH1355-2 Operation Instructions Download Page 2

6.Connect the other end of hose (built in

cushion

)to the screw thread of G12” inlet.

7. Place the main body of eye wash on the tray
8. Connect the inlet pipes, inspect whether the connects is firm, whether have leakage.
9.Test: draw out the eye wash, press down the Push button and push forward, then open

the switch, inspect whether sprayer head is smooth, whether have impurity is not clear,
the water beam is suitable for washing eyes. Test finished, pullback the push button
and loosen, then close the switch.

Instructions for use

When used, the extract eyewash body from the tray, press down the push button with the

thumb while pushing forward, switching valve to be opened and lock the water, that line

flushing, flushing is completed, pullback the button and release that switch off, and then

place the main body of eye wash on the tray

.

Troubleshooting suggestions:

No.

Fault

CAUSE

Remedy

1

Small water

flow of

nozzles

Inlet has stolen goods

nozzle hole are blocked

Low water pressure

Unscrew the nozzle

cleaning booty

Increase

water

pressure

2

Hose connections leaking

Cushion of connecting

nut damaged

Replace

the

cushion

Notices

1

If the pressure is less than 0.15Mpa, the water may cause adverse effects, above

0.5Mpa, will lead to the closure lax.

2

Should not be forced to reverse when extracting the main body of eye wash, bend the

hose should go with the flow.

Reviews: